Go to main content

Oracle® ZFS Storage Appliance Installation Guide

Exit Print View

Updated: January 2019
 
 

Overview of 7320 Controller

This section provides an overview of the Oracle ZFS Storage 7320 controller. For installation instructions, refer to Installing a 7x20 Controller. For service instructions, refer to Servicing the 7420 or 7320 Controller in Oracle ZFS Storage Appliance Customer Service Manual.

7320 Electrical Specifications

The following list shows the electrical specifications for the 7320 controller.


Note -  The power dissipation numbers listed are the maximum rated power numbers for the power supply. The numbers are not a rating of the actual power consumption of the appliance.

Connectors

  • Two C13 connectors, which work on 110-220v outlets

Input

  • Nominal frequencies: 50/60Hz

  • Nominal voltage range: 100-120/200-240 VAC

  • Maximum current AC RMS: 9.0 amps Max

  • AC operating range: 90-264 VAC

Output

  • 3.3 VDC STBY: 3.6A

  • +12 VDC: 62.3A

Power dissipation

  • Max power consumption: 873 W

  • Max heat output: 2977 BTU/hr

  • Volt-Ampere rating: 891 VA @ 240 VAC, 0.98P.F.

7320 Base Configurations

The 7320 controller base configuration options are:

  • Single or cluster

  • 24GB or 96GB RAM

  • 2x2.4GHz Quad-Core processors

  • One external SAS HBA

  • Four 10/100/1000 Ethernet ports

7320 Front Panel Components

The following figure and legend identify the front panel LEDs.

Figure 41  7320 Controller Front Panel

image:Graphic showing the components on the front panel of the                             controller

Figure Legend
1 Locate Button/LED
2 Service Required LED (amber)
3 Power/OK LED (green)
4 Power Button
5 Rear Power Supply
6 System Overtemperature LED
7 Top Fan

The following figure and legend identify the 7320 front panel drive locations. Two mirrored hard disk drives (HDDs) that store the operating system reside in slots 0 and 1. Up to four solid state drives (ReadZilla SSDs), which store the read cache, fill slots 2 through 5, in order. Slots 6 and 7 are empty and must contain drive fillers.

Figure 42  7320 Front Panel Drive Locations

image:Graphic showing the drive locations at the front of the                             controller

Disk Drive Locations
HDD1
HDD3
HDD5
HDD0
HDD2
HDD4
HDD6
HDD7

7320 Rear Panel Components

Following is an illustration of the 7320 storage controller rear panel. The Sun 375-3609 belongs in slot 2, cannot be installed in any other slots, and a second is not offered as an option.

For information about PCIe cards, see 7320 Configuration Options in Oracle ZFS Storage Appliance Customer Service Manual.

Figure 43  7320 Controller Rear Panel

image:Graphic showing the components located at the front of the                             controller

Figure Legend
1 Power supplies
2 SC summary status LEDs
3 Serial management port
4 Network management (NET MGT) 10/100 BASE-T Ethernet port
5 Ethernet ports
6 PCIe slots

The 7320 controller has the following ports:

  • Ethernet Ports - There are four RJ-45 Gigabit Ethernet ports (NET 0, NET 1, NET 2, NET 3) located on the motherboard that operate at 10/100/1000 Mbit/sec. These network interfaces must be configured before use.

  • Network Management Port - The network management connector (NET MGT) is an RJ-45 10/100 BASE-T Ethernet port and provides an alternate terminal interface to the SP console.

    image:Graphic showing the network management port

  • Serial Management Port - The serial management connector (SERIAL MGT) is an RJ-45 connector and is a terminal connection to the SP console.

    image:Graphic showing the serial management port