This section provides an overview of the Oracle ZFS Storage ZS5-2 controller. For installation instructions, refer to Installing a ZS5-2 Controller. For service instructions, refer to Servicing the ZS5-2 Controller in Oracle ZFS Storage Appliance Customer Service Manual.
Refer to http://oracle.com/zfsstorage for the most recent component specification.
The ZS5-2 controller chassis dimensions are as follows:
|
The ZS5-2 controller has two N+1 AC redundant hot-swappable AC power supplies, rated 91% efficiency. To understand the overall power consumption, see Oracle's online power calculator at http://www.oracle.com/goto/powercalculators.
|
In compliance with the requirements defined in ISO 9296, the workplace-dependent noise level of this product is less than 75 dBA.
The ZS5-2 incorporates one or two controllers and one to sixteen disk shelves. Each controller has six PCIe Gen3 slots. Each controller includes eight 2.5'' disk slots that accommodate two system disks. Read cache devices are installed in disk shelves; therefore, the remaining six disk slots have permanent filler panels. The following table describes the configuration options.
|
Refer to http://oracle.com/zfsstorage for the most recent component specification.
The ZS5-2 controller drive slots and front panel components are shown in the following figure.
Figure 26 ZS5-2 Front Panel
|
The ZS5-2 controller PCIe slots and rear panel components are shown in the following figure.
Figure 27 ZS5-2 Rear Panel
|
Cluster Interface Card Compatibility - The ZS5-2 controller contains a Version 3 cluster interface card, which is incompatible with Version 2.
For information about how to connect cables to form a cluster, see Connecting Cluster Cables in Oracle ZFS Storage Appliance Cabling Guide.
The following figure identifies the components of the cable management arm (CMA). For installation instructions, see Installing a ZS5-2 Cable Management Arm.
Figure 28 ZS5-2 Controller Cable Management Arm
|