Replaceable Units
The following table lists the replaceable units in the server and directs you to
the replacement instructions.
Note -
You can remove and replace hot-serviceable components while the server module
is operating in Main power mode. Service cold-service components when the server
module is powered off and, in most cases, when you remove them from the
server.
|
|
|
Battery
|
Lithium coin-cell battery that powers the CMOS BIOS and
real-time clock.
|
|
Air baffle
|
Aids in the cooling the system components.
|
|
DIMMs
|
Add or replace memory modules in the system.
|
|
Storage drives (HC only, hot service)
|
Storage drive configuration supports up to twelve 3.5-inch
hot-pluggable 10 TB HDDs.
|
|
Internal M.2 flash SSDs
|
Supports up to two internal M.2 flash SSDs.
|
|
Fan modules (hot service)
|
Four fan modules for cooling the server components.
|
|
PCIe cards (hot service)
|
Add-on cards that can expand the functionality of the
server.
|
|
Power supply units (PSUs, hot service)
|
Two fully redundant AC-powered power supplies.
|
|
Processor and heatsink (cold service)
|
Carries out the instructions of the system.
|
|
Disk backplane
|
Provides power and communications connectors for storage
drives.
|
|
SAS cables (HC only)
|
Provide signals between the front disk backplane and the
Oracle Storage 12 Gb SAS PCIe RAID HBA, Internal card (HC
only).
|
|
Oracle Storage 12 Gb SAS PCIe RAID HBA, Internal card (HC
only)
|
Located in PCIe slot 11, the Oracle Storage 12 Gb SAS PCIe
RAID HBA, Internal card manages SAS storage drives (HC
only).
|
|
Front LED indicator module
|
Contains the push-button circuitry and LEDs that are displayed
on the bezel of the chassis.
|
|
Motherboard assembly
|
Provides connectors for the DIMMs, processors, PCIe risers,
and other components.
|
|
|