Power On the Server

As soon as you connect the power cords, Standby power is applied. In Standby power mode:

  • The System OK LED on the server front panel blinks slowly.

  • The SP OK LED indicator is steady on.

  • The AC Power Supply indicator lights are steady on.

    Depending on the firmware configuration, the system might boot. If it does not boot, perform the following procedure.

  • Power on the server to Main power mode by performing one of the following actions:
    • Press the On/Standby button on the front bezel.
    • Log in to the Oracle ILOM web interface, click Host Management → Power Control, and from the Select Action list, select Power On.
    • Log in to the Oracle ILOM command-line interface (CLI), and type the following command at the Oracle ILOM prompt:
      -> start /System
      

      When the server is powered on to Main power mode and the power-on self-test (POST) code checkpoint tests are complete, the green System OK LED status indicator on the front panel of the server lights and remains lit.