Fan Events
The following table lists fan events.
|
|
SNMP Trap:
sunHwTrapFanSpeedCritThresholdExceeded
Oracle ILOM Event Message:
Lower critical threshold exceeded
Severity and Description:
Major; A fan speed sensor reported that its value went above an
upper critical threshold setting or below a lower critical threshold
setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/MB/FM[0-3]/F[0-x]/TACH
|
SNMP Trap:
sunHwTrapFanSpeedCritThresholdDeasserted
Oracle ILOM Event Message:
Lower critical threshold no longer exceeded
Severity and Description:
Informational; A fan speed sensor reported that its value
went below an upper critical threshold setting or above a lower
critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/MB/FM[0-3]/F[0-x]/TACH
|
SNMP Trap:
sunHwTrapFanSpeedFatalThresholdExceeded
Oracle ILOM Event Message:
Lower fatal threshold exceeded
Severity and Description:
Critical; A fan speed sensor reported that its value went above an
upper fatal threshold setting or below a lower fatal threshold
setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/MB/FM[0-3]/F[0-x]/TACH
|
SNMP Trap:
sunHwTrapFanSpeedFatalThresholdDeasserted
Oracle ILOM Event Message:
Lower fatal threshold no longer exceeded
Severity and Description:
Informational; A fan speed sensor reported that its value went below
an upper fatal threshold setting or above a lower fatal threshold
setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/MB/FM[0-3]/F[0-x]/TACH
|
|