Go to main content

Oracle® Exadata Storage Server X7-2 EF and HC Service Manual

Exit Print View

Updated: April 2019
 
 

Fan Events

The following table lists fan events.

Messages and Descriptions
Component Name
SNMP Trap: sunHwTrapFanSpeedCritThresholdExceeded
Oracle ILOM Event Message: Lower critical threshold exceeded
Severity and Description: Major; A fan speed sensor reported that its value went above an upper critical threshold setting or below a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.
/SYS/MB/FM[0-3]/F[0-x]/TACH
SNMP Trap: sunHwTrapFanSpeedCritThresholdDeasserted
Oracle ILOM Event Message: Lower critical threshold no longer exceeded
Severity and Description: Informational; A fan speed sensor reported that its value went below an upper critical threshold setting or above a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.
/SYS/MB/FM[0-3]/F[0-x]/TACH
SNMP Trap: sunHwTrapFanSpeedFatalThresholdExceeded
Oracle ILOM Event Message: Lower fatal threshold exceeded
Severity and Description: Critical; A fan speed sensor reported that its value went above an upper fatal threshold setting or below a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.
/SYS/MB/FM[0-3]/F[0-x]/TACH
SNMP Trap: sunHwTrapFanSpeedFatalThresholdDeasserted
Oracle ILOM Event Message: Lower fatal threshold no longer exceeded
Severity and Description: Informational; A fan speed sensor reported that its value went below an upper fatal threshold setting or above a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower threshold.
/SYS/MB/FM[0-3]/F[0-x]/TACH

Related Information