Install a Fan Module

  1. Remove the replacement fan module from its packaging, and place it on an antistatic mat.
  2. With the server top cover removed, install the replacement fan module into the server.

    The fan modules are keyed to ensure that they are installed in the correct orientation.


    image:Figure showing how to install a fan module.
  3. Press down on the fan module to fully seat the fan module.
  4. Verify that the fan module status indicator (LED) on the replacement fan module is not illuminated.
  5. Install the server top cover.

    See Install the Server Top Cover.

  6. Verify that the Top Fan Fault LED on the front of the server and the Fault-Service Required LEDs on the front and back of the server are off.

    See Server System-Level Status Indicators for more information about identifying and interpreting system status indicators.

  7. Consider your next step:
    • If you installed the fan module as part of another procedure, return to that procedure.

    • Otherwise, if you powered off the server, return the server to operation. See Returning the Server to Operation.