Skip Navigation Links | |
Exit Print View | |
Sun Network QDR InfiniBand Gateway Switch HTML Document Collection for Firmware Version 2.1 |
USB Management Connector and Pins
Preparing to Install the Gateway
Suggested Tools for Installation
Antistatic Precautions for Installation
Verify Shipping Carton Contents
Assemble the Optical Fiber Data Cables
Install the Gateway in the Rack
Verifying the InfiniBand Fabric
Network Management Troubleshooting Guidelines
Understanding Routing Through the Gateway
Understanding Administrative Commands
Administering the I4 Switch Chip
Controlling the I4 Switch Chip
Administering the Subnet Manager
Controlling the Subnet Manager
Configuring Secure Fabric Management
Administering the InfiniBand Fabric
Monitoring the InfiniBand Fabric
Controlling the InfiniBand Fabric
Administering Gateway Resources
Installing Gateway Supportive Software (Linux)
Creating VNICs Under Gateway Manual Mode (Linux)
Creating VNICs Under Host Manual Mode (Linux)
Creating Virtual IO Adapters (Oracle Solaris)
Controlling Gateway Ports and Parameters
Understanding Oracle ILOM on the Gateway
Understanding Oracle ILOM Targets
Administering Oracle ILOM (CLI)
Accessing Oracle ILOM From the CLI
Switching Between the Oracle ILOM Shell and the Linux Shell
Monitoring Oracle ILOM Targets (CLI)
Controlling Oracle ILOM Targets (CLI)
Upgrading the Gateway Firmware Through Oracle ILOM (CLI)
Administering Oracle ILOM (Web)
Access Oracle ILOM From the Web Interface
Monitoring Oracle ILOM Targets (Web)
Controlling Oracle ILOM Targets (Web)
Upgrade the Gateway Firmware (Web)
Accessing the Rear Panel Diagram
Accessing Status Pane Information
Monitoring Parameters and Status
Administering Oracle ILOM (SNMP)
Monitoring Oracle ILOM Targets (SNMP)
Controlling Oracle ILOM Targets (SNMP)
Display the Sensor States (IPMI)
Display the Sensor Information (IPMI)
Display the System Event Log (IPMI)
Display FRU ID Information (IPMI)
Display Gateway Status LED States (IPMI)
Disable the Locator LED (IPMI)
Understanding Oracle ILOM Commands
Identify Faults in the Oracle ILOM Event Log
Determining the Alarm State of a Component or System
Understanding Service Procedures
Antistatic Precautions for Service
Determine If a Power Supply Is Faulty
Determine If the Battery Is Faulty
Remove the Gateway From the Rack
Understanding Hardware Commands
Linux Shells for Hardware Commands
Understanding InfiniBand Commands
Linux Shells for InfiniBand Commands
Understanding the SUN-DCS-IB-MIB MIB OIDs
Understanding the SUN-FABRIC-MIB MIB OIDs
Understanding the SUN-HW-TRAP-MIB MIB OIDs
Understanding the SUN-ILOM-CONTROL-MIB MIB OIDs
Understanding the SUN-PLATFORM-MIB MIB OIDs
Displays environmental status.
env_test
This hardware command performs a series of hardware and environmental tests of the gateway. This command is an amalgamation of these commands:
checkpower
checkvoltages
showtemps
getfanspeed
connector
checkboot
The command output provides voltage and temperature values, pass-fail results, and error messages.
The env_test command is available from the /SYS/Switch_Diag, /SYS/Gateway_Mgmt, and /SYS/Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface.
This example shows how to display the hardware and environmental status of the gateway with the env_test command.
FabMan@gateway_name->env_test Environment test started: Starting Environment Daemon test: Environment daemon running Environment Daemon test returned OK Starting Voltage test: Voltage ECB OK Measured 3.3V Main = 3.28 V Measured 3.3V Standby = 3.37 V Measured 12V = 12.06 V Measured 5V = 5.03 V Measured VBAT = 3.25 V Measured 1.0V = 1.01 V Measured I4 1.2V = 1.22 V Measured 2.5V = 2.51 V Measured V1P2 DIG = 1.18 V Measured V1P2 ANG = 1.18 V Measured 1.2V BridgeX = 1.22 V Measured 1.8V = 1.80 V Measured 1.2V Standby = 1.20 V Voltage test returned OK Starting PSU test: PSU 0 present PSU 1 present PSU test returned OK Starting Temperature test: Back temperature 30.5 Front temperature 30.6 SP temperature 34.1 Switch temperature 48, maxtemperature 49 Bridge-0 temperature 40, maxtemperature 41 Bridge-1 temperature 45, maxtemperature 45 Temperature test returned OK Starting FAN test: Fan 0 not present Fan 1 running at rpm 12075 Fan 2 running at rpm 11960 Fan 3 running at rpm 12075 Fan 4 not present FAN test returned OK Starting Connector test: Connector test returned OK Starting Onboard ibdevice test: Switch OK Bridge-0 OK Bridge-1 OK All Internal ibdevices OK Onboard ibdevice test returned OK Starting SSD test: SSD test returned OK Environment test PASSED FabMan@gateway_name->