Server Specifications

This section includes physical, electrical and environmental specifications for the system.

Physical Specifications

The following table lists the physical specifications for the Sun Server X4-8.

Parameter
Value
Height
5U / 219.25 mm (8.63 in.)
Width
445 mm (17.5 in.)
Depth
834 mm (32.8 in.)
Weight
114 kg (250 lbs)

Electrical Specifications

The following table lists the electrical specifications for the Sun Server X4-8.


Note -  For up-to-date information on power consumption, go to the Sun x86 Servers web site and navigate to the Sun Server X4-8 page:

http://www.oracle.com/technetwork/server-storage/sun-x86/overview/index.html


Parameter
Value
Nominal input frequencies
50/60 Hz
Operating input voltage range
200-240 VAC
Rated input current
23A @ 200 to 230 VAC
12A max per cord
Maximum power consumption
3400 W
Maximum heat output
11600 BTU/Hr

Environmental Requirements

The following table lists the environmental requirements for the Sun Server X4-8.

Parameter
Value
Operating temperature (single, non-rack system)
At sea level: 5° C to 35° C (41° F to 95° F)
At altitude: 5° C to 31° C (41° F to 88° F)
Operating temperature
5° C to 35° C (4° F to 95° F)
Non-operating temperature
-40 °C to 70 °C (-40 °F to 158° F)
Operating humidity
10% to 90% relative humidity, non-condensing
Non-operating humidity
Up to 93% relative humidity, non-condensing
Operating altitude
Up to 3,000 m (9,840 ft), maximum ambient temperature is derated by 1 degree C per 300m above 900 m, except in China where regulations may limit installations to a maximum altitude of 2,000 m
Non-operating altitude
0 m to 12,000 m (0 ft to 40,000 ft)
Acoustic noise
Acoustic noise: 7.7 B operating, 6.8 B idling - (LwAd: 1 B=10 dB)