Install the Server (4-Post, 19-Inch Hardmount Rack Kit)


Caution

Caution  -  You must install the server into a rack following these instructions for the 4-post, 19-inch hardmount kit. If you deviate from these instructions when installing the server, your installation will not be supported.


  1. Gather the required tools.

    See Tools Needed for Installation.

  2. Read the server cautions.

    See Handling Precautions and ESD Precautions.

  3. Read the rack cautions and stabilize the rack.

    See Rack Cautions and Stabilize the Rack.

  4. If you are changing the rack kit on an existing server in your data center, perform these steps:
    1. Shut down the server, and remove the power and data cables.
    2. Remove the server from the rack, and place it on an antistatic mat.
    3. Remove the existing mounting brackets from the server and rack, if applicable.
  5. Secure the hardmount brackets to the sides of the server.

    Use four M5 x 4.5 mm flathead Phillips screws for each bracket.


    image:Figure showing how to install the two hardmount brackets to the                                 server.
  6. Measure the depth of the rack.

    The measurement is used in the next step.

  7. Install the rear mount support brackets at the rear of the server, extending the rear mount support brackets to the measured depth of the rack.

    Use two to three of the supplied M4 x 0.5 x 5 mm panhead Phillips screws for each bracket, depending on the rack depth.


    image:Figure showing where to install the two rear mount support                                 brackets.
  8. Lift the server to the desired location in the rack.
  9. Secure the front of the hardmount brackets.

    Use two screws for each post.


    image:Figure showing where to secure the front hardmount                                 brackets.
  10. Secure the rear mount support brackets to the rear of the rack.

    Use two screws for each rear mount support bracket.


    image:Figure showing how to secure the rear of the server into a                                 rack.
  11. Connect required and optional cables.

    See Connecting Cables.

  12. Consider your next step:
    • For existing servers, return the server to operation by following the steps in the service manual.
    • For new servers, continue the installation by following the steps in Connecting Cables.

Related Information