Go to main content
Sun Datacenter InfiniBand Switch 36 Documentation Supplement for Firmware Version 2.2

Exit Print View

Updated: September 2016
 
 

Oracle ILOM Legacy Targets and Properties

This table lists new Oracle ILOM /SYS targets and their properties, and new properties for firmware 2.2.

Target and Path
Properties and Default Values
/SYS
  • fault_state = OK

  • clear_fault_action = (none)

/SYS/LINKDISABLE_ATTN
  • type = OEM

  • ipmi_name = LINKDISABLE_ATTN

  • class = Discrete Sensor

  • value = State Deasserted

  • alarm_status = cleared

/SYS/MB
fru_serial_number = 465769T+1234R601F3
/SYS/MB/T_BACK
  • upper_nonrecov_threshold = 65.000 degree C

  • upper_critical_threshold = 60.000 degree C

/SYS/MB/T_FRONT
  • upper_nonrecov_threshold = 65.000 degree C

  • upper_critical_threshold = 60.000 degree C

/SYS/MB/T_I4A
  • upper_nonrecov_threshold = 95.000 degree C

  • upper_critical_threshold = 90.000 degree C

/SYS/MB/T_SP
  • upper_nonrecov_threshold = 85.000 degree C

  • upper_critical_threshold = 80.000 degree C

Related Information