Install the NVMe Cables

This is a cold-service procedure that must be performed by qualified service personnel. The server must be completely powered down before performing this procedure.

  1. Guide the NVMe card cables along the side of the chassis.
    image:Image showing install of NMMe cables.
  2. Connect the cables to the drive backplane (1).
    1. Connect the cable labeled "A" to the connector on the drive backplane labeled "NMVe A".
    2. Connect the cable labeled "B" to the connector on the drive backplane labeled "NMVe B".
  3. Connect the NVMe card cables to the motherboard (2).
    1. Connect the cable labeled "2,3" to the connector on the motherboard labeled "2,3".

      This is the connector closer to the front of the server.

    2. Connect the cable labeled "0,1" to the connector on the motherboard labeled "0,1".

      This is the connector closer to the rear of the server.

  4. Install the server fan modules.

    See Install a Fan Module.

  5. Install the server mid-wall (3).
    1. Position the mid-wall over the front of the motherboard so that it engages the mushroom-shaped standoffs that are located on the server chassis sidewall.
    2. Ensure that SAS cables are not pinched by the mid-wall and that they run beside the mid-wall and not under it.
    3. Tighten the four green captive screws to secure the mid-wall to the server chassis, use No. 2 Phillips screwdriver.
  6. Replace the air baffle.
  7. Return the server to operation.

    See Returning the Server to Operation.