Install the NVMe Cables
This is a cold-service procedure that must be performed by qualified service
personnel. The server must be completely powered down before performing this
procedure.
-
Guide the NVMe card cables along the side of the chassis.
-
Connect the cables to the drive backplane (1).
-
Connect the cable labeled "A" to the connector on the drive backplane
labeled "NMVe A".
-
Connect the cable labeled "B" to the connector on the drive backplane
labeled "NMVe B".
-
Connect the NVMe card cables to the motherboard (2).
-
Connect the cable labeled "2,3" to the connector on the motherboard
labeled "2,3".
This is the connector closer to the front of the server.
-
Connect the cable labeled "0,1" to the connector on the motherboard
labeled "0,1".
This is the connector closer to the rear of the server.
-
Install the server fan modules.
See Install a Fan Module.
-
Install the server mid-wall (3).
-
Position the mid-wall over the front of the motherboard so that it
engages the mushroom-shaped standoffs that are located on the server
chassis sidewall.
-
Ensure that SAS cables are not pinched by the mid-wall and that they
run beside the mid-wall and not under it.
-
Tighten the four green captive screws to secure the mid-wall to the
server chassis, use No. 2 Phillips screwdriver.
-
Replace the air baffle.
-
Return the server to operation.
See Returning the Server to Operation.