Install a Fan Module
This is a hot-service procedure that can be performed by a customer while the
server is running.
-
Remove the replacement fan module from its packaging and place it on an
antistatic mat.
-
With the fan door open, position the replacement fan module into the
server.
The fan modules are keyed to ensure that they are installed correctly.
-
Press down on the fan module and apply firm pressure to fully seat the fan
module.
-
Verify that the fan module status indicator (LED) that aligns with the
replaced fan module is extinguished.
-
Close the fan door.
-
Verify that the Top Fan Fault LED on the front of the server and the Service
Required LEDs on the front and rear of the server are extinguished.
-
Consider your next step:
-
If you installed the fan module as part of another procedure, return
to that procedure.
-
Otherwise, return the server to operation. See Returning the Server to Operation.