JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Datacenter InfiniBand Switch 36 HTML Document Collection for Firmware Version 2.1
search filter icon
search icon

Document Information

Using This Documentation

Product Notes

Related Documentation

Feedback

Access to Oracle Support

Installation

Understanding the Switch

Switch Overview

Physical Specifications

Environmental Requirements

Acoustic Noise Emissions

Electrical Specifications

NET MGT Connector and Pins

USB Management Connector and Pins

InfiniBand QSFP Connector and Pins

Understanding Cabling

Routing Service Cables

Understanding InfiniBand Cabling

Preparing to Install the Switch

Installation Preparation

Suggested Tools for Installation

Antistatic Precautions for Installation

Installation Responsibilities

Installation Sequence

Verify Shipping Carton Contents

Assemble the Optical Fiber InfiniBand Cables

Route the InfiniBand Cables

Installing the Switch

Install the Switch in the Rack

Powering On the Switch

Connecting InfiniBand cables

Verifying the InfiniBand Fabric

Administration

Troubleshooting the Switch

Switch Hardware Problems

InfiniBand Fabric Problems

Network Management Troubleshooting Guidelines

Understanding Routing Through the Switch

Switch GUIDs Overview

Understanding Administrative Commands

Configuration Overview

Oracle ILOM Command Overview

Hardware Command Overview

InfiniBand Command Overview

Administering the Chassis

Monitoring the Chassis

Controlling the Chassis

Administering the I4 Switch Chip

Monitoring the I4 Switch Chip

Controlling the I4 Switch Chip

Administering the Subnet Manager

Monitoring the Subnet Manager

Controlling the Subnet Manager

Configuring Secure Fabric Management

Administering the InfiniBand Fabric

Monitoring the InfiniBand Fabric

Controlling the InfiniBand Fabric

Remote Management

Understanding Oracle ILOM on the Switch

Oracle ILOM Overview

Supported Features

Understanding Oracle ILOM Targets

Oracle ILOM Target Overview

Oracle ILOM Targets and Descriptions

Oracle ILOM General System Targets and Properties

Oracle ILOM Fan Targets and Properties

Oracle ILOM Indicator Targets and Properties

Oracle ILOM Power Supply Targets and Properties

Oracle ILOM Temperature Targets and Properties

Oracle ILOM Voltage Targets and Properties

Oracle ILOM Voltage State Targets and Properties

Oracle ILOM General Targets and Properties

Oracle ILOM Service Targets and Properties

Oracle ILOM User and Session Targets and Properties

Administering Oracle ILOM (CLI)

CLI Overview

Accessing Oracle ILOM From the CLI

Switching Between the Oracle ILOM Shell and the Linux Shell

Monitoring Oracle ILOM Targets (CLI)

Controlling Oracle ILOM Targets (CLI)

Upgrading the Switch Firmware Through Oracle ILOM (CLI)

Administering Oracle ILOM (Web)

Web Interface Overview

Access Oracle ILOM From the Web Interface

Monitoring Oracle ILOM Targets (Web)

Controlling Oracle ILOM Targets (Web)

Upgrade the Switch Firmware (Web)

Using the Fabric Monitor

Access the Fabric Monitor

Fabric Monitor Features

Accessing the Rear Panel Diagram

Accessing Status Pane Information

Control Panel Function

Monitoring Parameters and Status

Administering Oracle ILOM (SNMP)

SNMP Overview

Understanding SNMP Commands

Monitoring Oracle ILOM Targets (SNMP)

Controlling Oracle ILOM Targets (SNMP)

Administering Hardware (IPMI)

ipmitool Overview

Display the Sensor States (IPMI)

Display the Sensor Information (IPMI)

Display the System Event Log (IPMI)

Display FRU ID Information (IPMI)

Display Switch Status LED States (IPMI)

Enable the Locator LED (IPMI)

Disable the Locator LED (IPMI)

Understanding Oracle ILOM Commands

cd Command

create Command

delete Command

dump Command

exit Command (Oracle ILOM)

help Command (Oracle ILOM)

load Command

reset Command

set Command

show Command

version Command (Oracle ILOM)

Service

Detecting and Managing Faults

Interpreting Status LEDs

Managing Faulty Components

Identify Faults in the Oracle ILOM Event Log

Determining the Alarm State of a Component or System

Evaluating Sensor Alarms

Accessing CLI Prompts

Understanding Service Procedures

Replaceable Components

Suggested Tools for Service

Antistatic Precautions for Service

Servicing Power Supplies

Determine If a Power Supply Is Faulty

Inspecting a Power Supply

Power Off a Power Supply

Remove a Power Supply

Install a Power Supply

Power On a Power Supply

Servicing Fans

Determine If a Fan Is Faulty

Inspecting a Fan

Remove a Fan

Install a Fan

Servicing InfiniBand Cables

Inspecting the InfiniBand Cables

Remove an InfiniBand Cable

Install an InfiniBand Cable

Servicing the Battery

Determine If the Battery Is Faulty

Remove the Switch From the Rack

Replace the Battery

Reference

Understanding Hardware Commands

Linux Shells for Hardware Commands

autodisable Command

checkboot Command

checkpower Command

checktopomax Command

checkvoltages Command

connector Command

create_ipoib Command

createfabric Command

dcsport Command

delete_ipoib Command

disablecablelog Command

disablelinklog Command

disablesm Command

disableswitchport Command

enablecablelog Command

enablelinklog Command

enablesm Command

enableswitchport Command

env_test Command

exit Command (Hardware)

fdconfig Command

fwverify Command

generatetopology Command

getfanspeed Command

getmaster Command

getportcounters Command

getportstatus Command

help Command (Hardware)

listlinkup Command

localmkeypersistence Command

matchtopology Command

setcontrolledhandover Command

setmsmlocationmonitor Command

setsmmkey Command

setsmpriority Command

setsmrouting Command

setsubnetprefix Command

showdisk Command

showfree Command

showfruinfo Command

showpsufru Command

showsmlog Command

showtemps Command

showtopology Command

showunhealthy Command

smconfigtest Command

smnodes Command

smpartition Command

smsubnetprotection Command

version Command (Hardware)

Understanding InfiniBand Commands

Linux Shells for InfiniBand Commands

ibdiagnet Command

ibhosts Command

ibnetdiscover Command

ibnetstatus Command

ibnodes Command

ibportstate Command

ibroute Command

ibrouters Command

ibstat Command

ibswitches Command

ibtracert Command

perfquery Command

saquery Command

smpquery Command

Understanding SNMP MIB OIDs

OID Tables Overview

Understanding the SUN-DCS-IB-MIB MIB OIDs

Understanding the SUN-FABRIC-MIB MIB OIDs

Understanding the SUN-HW-TRAP-MIB MIB OIDs

Understanding the SUN-ILOM-CONTROL-MIB MIB OIDs

Understanding the SUN-PLATFORM-MIB MIB OIDs

Understanding the ENTITY-MIB MIB OIDs

Index

Oracle ILOM Targets and Descriptions

This table lists the Oracle ILOM targets supported in the switch and provides a short description of the target.

Oracle ILOM Target
Description
/
Hierarchy root
/SP
Management controller or Host
/SP/alertmgmt/rules
Alert rules
/SP/cli
CLI
/SP/clients
Clients that connect to external services
/SP/clients/dns
DNS client configuration
/SP/clients/ntp
NTP configuration
/SP/clients/ntp/server
NTP server configuration
/SP/clients/smtp
SMTP email client configuration
/SP/clients/syslog
syslogd management
/SP/clock
Clock management
/SP/config
Configuration back up and restore settings
/SP/diag/snapshot
State of switch snapshot
/SP/Fabric_Mgmt
Fabric management Linux shell (ilom-admin user)
/SP/faultmgmt
List of faulted components
/SP/logs/event
Event log management
/SP/logs/event/list
List of events
/SP/network
External network interface
/SP/network/test
Ping test
/SP/Platform_CLI
Comprehensive Linux shell
/SP/services
Available services
/SP/services/http
HTTP service
/SP/services/https
HTTPS service
/SP/services/https/ssl
HTTPS SSL certificate settings
/SP/services/https/ssl/custom_cert
Custom SSL certificate settings
/SP/services/https/ssl/custom_key
Custom SSL private key settings
/SP/services/https/ssl/default_cert
Default SSL certificate settings
/SP/services/ipmi
Management of the IPMI service
/SP/services/servicetag
Service Tag configuration
/SP/services/snmp
SNMP agent service configuration
/SP/services/snmp/communities/private
SNMP community
/SP/services/snmp/communities/public
SNMP community
/SP/services/snmp/mibs
SNMP MIBs downloadable
/SP/services/snmp/users
SNMP users
/SP/sessions
Monitor active user sessions
/SP/Switch_Diag
Diagnostic Linux shell (ilom-operator and ilom-admin users)
/SP/users
User management
/SP/users/root
User root role and password
/SP/users/ilom-admin
User ilom-admin role and password
/SP/users/ilom-operator
User ilom-operator role and password
/SYS
Sensors and FRU information
/SYS/CABLE_ATTN
Aggregate sensor – Overall connector hardware state
/SYS/CABLE_CONN_STAT
Aggregate sensor – Change in cable connectivity state
/SYS/CHASSIS_STATUS
Aggregate sensor – Overall chassis state
/SYS/COOLING_ATTN
Aggregate sensor – Overall cooling state
/SYS/COOLING_REDUN
Aggregate sensor – Cooling redundancy state
/SYS/Fabric_Mgmt
Fabric management Linux shell (ilom-admin user)
/SYS/FANx
Fan x information
/SYS/FANx/FAULT
Fault state of fan x
/SYS/FANx/PRSNT
Presence of fan x
/SYS/FANx/TACH
Speed of fan x
/SYS/I_ATTENTION
State of Attention LED
/SYS/I_LOCATOR
State of Locator LED
/SYS/I_POWER
State of Power LED
/SYS/IBDEV_ATTN
Aggregate sensor – Overall I4 switch chip state
/SYS/MB
Motherboard information
/SYS/MB/BAT_FAULT
State of the real time clock battery.
/SYS/MB/BOOT_I4A
Status of I4 switch chip boot
/SYS/MB/DISK_FAULT
State of the life span of the flash drive.
/SYS/MB/T_BACK
Temperature at rear of chassis
/SYS/MB/T_FRONT
Temperature at front of chassis
/SYS/MB/T_I4A
Temperature of the I4 switch chip
/SYS/MB/T_SP
Temperature of the management controller
/SYS/MB/V_1.8V
Voltage of the main 1.8V source
/SYS/MB/V_1.8VOK
State of the main 1.8V source
/SYS/MB/V_2.5V
Voltage of the main 2.5V source
/SYS/MB/V_2.5VOK
State of the main 2.5V source
/SYS/MB/V_3.3VMain
Voltage of the main 3.3V source
/SYS/MB/V_3.3VMainOK
State of the main 3.3V source
/SYS/MB/V_3.3VStby
Voltage of the standby 3.3V source
/SYS/MB/V_5V
Voltage of the main 5V source
/SYS/MB/V_5VOK
State of the main 5V source
/SYS/MB/V_12V
Voltage of the main 12V source
/SYS/MB/V_BAT
Voltage of the battery
/SYS/MB/V_ECB
State of the Electronic Circuit Breaker
/SYS/MB/V_I41.2V
Voltage of the I4 switch chip
/SYS/MB/V_I41.2VOK
State of the I4 switch chip 1.2V source
/SYS/Platform_CLI
Comprehensive Linux shell
/SYS/POWER_ATTN
Aggregate sensor – Overall power state
/SYS/POWER_REDUN
Aggregate sensor – Power redundancy state
/SYS/PSUx
Power supply x information
/SYS/PSUx/AC_PRESENT
Presence of AC input power for power supply x
/SYS/PSUx/ALERT
State of power supply x
/SYS/PSUx/FAULT
Fault state of power supply x
/SYS/PSUx/PRSNT
Presence of power supply x
/SYS/Switch_Diag
Diagnostic Linux shell (ilom-operator and ilom-admin users)
/SYS/TEMP_ATTN
Aggregate sensor – Overall temperature state
Related Information