JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Network QDR InfiniBand Gateway Switch HTML Document Collection for Firmware Version 2.1
search filter icon
search icon

Document Information

Using This Documentation

Product Notes

Related Documentation

Feedback

Access to Oracle Support

Installation

Understanding the Gateway

Gateway Overview

Physical Specifications

Environmental Requirements

Acoustic Noise Emissions

Electrical Specifications

NET MGT Connector and Pins

USB Management Connector and Pins

Data QSFP Connector and Pins

Understanding Cabling

Routing Service Cables

Understanding Data Cabling

Preparing to Install the Gateway

Installation Preparation

Suggested Tools for Installation

Antistatic Precautions for Installation

Installation Responsibilities

Installation Sequence

Verify Shipping Carton Contents

Assemble the Optical Fiber Data Cables

Route the Data Cables

Installing the Gateway

Install the Gateway in the Rack

Powering On the Gateway

Connecting Data cables

Verifying the InfiniBand Fabric

Administration

Troubleshooting the Gateway

Gateway Hardware Problems

InfiniBand Fabric Problems

Network Management Troubleshooting Guidelines

Understanding Routing Through the Gateway

Switch GUIDs Overview

Understanding Administrative Commands

Configuration Overview

Oracle ILOM Command Overview

Hardware Command Overview

InfiniBand Command Overview

Administering the Chassis

Monitoring the Chassis

Controlling the Chassis

Administering the I4 Switch Chip

Monitoring the I4 Switch Chip

Controlling the I4 Switch Chip

Administering the Subnet Manager

Monitoring the Subnet Manager

Controlling the Subnet Manager

Configuring Secure Fabric Management

Administering the InfiniBand Fabric

Monitoring the InfiniBand Fabric

Controlling the InfiniBand Fabric

Administering Gateway Resources

Installing Gateway Supportive Software (Linux)

Creating VNICs Under Gateway Manual Mode (Linux)

Creating VNICs Under Host Manual Mode (Linux)

Creating Virtual IO Adapters (Oracle Solaris)

Monitoring Gateway Resources

Controlling LAGs

Controlling VLANs and VNICs

Controlling Gateway Ports and Parameters

Remote Management

Understanding Oracle ILOM on the Gateway

Oracle ILOM Overview

Supported Features

Understanding Oracle ILOM Targets

Administering Oracle ILOM (CLI)

CLI Overview

Accessing Oracle ILOM From the CLI

Switching Between the Oracle ILOM Shell and the Linux Shell

Monitoring Oracle ILOM Targets (CLI)

Controlling Oracle ILOM Targets (CLI)

Upgrading the Gateway Firmware Through Oracle ILOM (CLI)

Administering Oracle ILOM (Web)

Web Interface Overview

Access Oracle ILOM From the Web Interface

Monitoring Oracle ILOM Targets (Web)

Controlling Oracle ILOM Targets (Web)

Upgrade the Gateway Firmware (Web)

Using the Fabric Monitor

Access the Fabric Monitor

Fabric Monitor Features

Accessing the Rear Panel Diagram

Accessing Status Pane Information

Control Panel Function

Monitoring Parameters and Status

Administering Oracle ILOM (SNMP)

SNMP Overview

Understanding SNMP Commands

Monitoring Oracle ILOM Targets (SNMP)

Controlling Oracle ILOM Targets (SNMP)

Administering Hardware (IPMI)

ipmitool Overview

Display the Sensor States (IPMI)

Display the Sensor Information (IPMI)

Display the System Event Log (IPMI)

Display FRU ID Information (IPMI)

Display Gateway Status LED States (IPMI)

Enable the Locator LED (IPMI)

Disable the Locator LED (IPMI)

Understanding Oracle ILOM Commands

cd Command

create Command

delete Command

dump Command

exit Command (Oracle ILOM)

help Command (Oracle ILOM)

load Command

reset Command

set Command

show Command

version Command (Oracle ILOM)

Service

Detecting and Managing Faults

Interpreting Status LEDs

Front Panel LEDs

Rear Panel LEDs

Check Chassis Status LEDs

Check NET MGT Port Status LEDs

Check Link Status LEDs

Check Power Supply Status LEDs

Check Fan Status LEDs

Managing Faulty Components

Display Faulty Components (fault_state)

Display Faulty Components (/SP/faultmgmt)

Clear a Fault Manually

Clearable Fault Targets

Identify Faults in the Oracle ILOM Event Log

Determining the Alarm State of a Component or System

Display the General Alarm State of Systems and Components

System Alarm Targets

Component Alarm Targets

Oracle ILOM Target Alarm States

Evaluating Sensor Alarms

Display Oracle ILOM Sensor Status

Determine Oracle ILOM Sensor Target Types

Evaluating a Voltage Sensor Alarm

Evaluate a Voltage Sensor

Voltage Sensor Values

Voltage Out of Range

Evaluating a Temperature Sensor Alarm

Evaluate a Temperature Sensor

Temperature Sensor Values

Temperature Out of Range

Evaluating a Speed Sensor Alarm

Evaluate a Speed Sensor

Speed Sensor Values

Speed Out of Range

Evaluating a State Sensor Alarm

Evaluate a State Sensor

State Sensor Alarm Conditions

Evaluating a Presence Sensor Alarm

Evaluate a Presence Sensor

Presence Sensor Alarm Conditions

Evaluating an Indicator State

Evaluate an Indicator State

Indicator State Values

Indicator State Conditions

Accessing CLI Prompts

Access the Oracle ILOM CLI (NET MGT Port)

Enter the Restricted Linux Shell

Exit the Restricted Linux Shell

Understanding Service Procedures

Replaceable Components

Suggested Tools for Service

Antistatic Precautions for Service

Servicing Power Supplies

Determine If a Power Supply Is Faulty

Inspecting a Power Supply

Power Off a Power Supply

Remove a Power Supply

Install a Power Supply

Power On a Power Supply

Servicing Fans

Determine If a Fan Is Faulty

Inspecting a Fan

Remove a Fan

Install a Fan

Servicing Data Cables

Inspecting the Data Cables

Remove a Data Cable

Install a Data Cable

Servicing the Battery

Determine If the Battery Is Faulty

Remove the Gateway From the Rack

Replace the Battery

Reference

Understanding Hardware Commands

Linux Shells for Hardware Commands

addlagport Command

allowhostconfig Command

autodisable Command

checkboot Command

checkpower Command

checktopomax Command

checkvoltages Command

connector Command

create_ipoib Command

createfabric Command

createlag Command

createvlan Command

createvnic Command

dcsport Command

delete_ipoib Command

deletelag Command

deletevlan Command

deletevnic Command

dellagport Command

disablecablelog Command

disablegwport Command

disablelagmode Command

disablelinklog Command

disablesm Command

disableswitchport Command

disablevnic Command

disallowhostconfig Command

enablecablelog Command

enablegwport Command

enablelagmode Command

enablelinklog Command

enablesm Command

enableswitchport Command

enablevnic Command

env_test Command

exit Command (Hardware)

fdconfig Command

fwverify Command

generatetopology Command

getfanspeed Command

getmaster Command

getportcounters Command

getportstatus Command

help Command (Hardware)

listlinkup Command

localmkeypersistence Command

matchtopology Command

modifyvnic Command

setcontrolledhandover Command

setdefaultgwdiscpkey Command

setgwethport Command

setgwinstance Command

setgwsl Command

setgwsystemname Command

sethostvniclimit Command

setmsmlocationmonitor Command

setsmmkey Command

setsmpriority Command

setsmrouting Command

setsubnetprefix Command

showdisk Command

showfree Command

showfruinfo Command

showgwconfig Command

showgwports Command

showioadapters Command

showlag Command

showpsufru Command

showsmlog Command

showtemps Command

showtopology Command

showunhealthy Command

showvlan Command

showvnics Command

smconfigtest Command

smnodes Command

smpartition Command

smsubnetprotection Command

version Command (Hardware)

Understanding InfiniBand Commands

Linux Shells for InfiniBand Commands

ibdiagnet Command

ibhosts Command

ibnetdiscover Command

ibnetstatus Command

ibnodes Command

ibportstate Command

ibroute Command

ibrouters Command

ibstat Command

ibswitches Command

ibtracert Command

perfquery Command

saquery Command

smpquery Command

Understanding SNMP MIB OIDs

OID Tables Overview

Understanding the SUN-DCS-IB-MIB MIB OIDs

Understanding the SUN-FABRIC-MIB MIB OIDs

Understanding the SUN-HW-TRAP-MIB MIB OIDs

Understanding the SUN-ILOM-CONTROL-MIB MIB OIDs

Understanding the SUN-PLATFORM-MIB MIB OIDs

Understanding the ENTITY-MIB MIB OIDs

Index

Display Oracle ILOM Sensor Status

  1. Access the Oracle ILOM CLI.

    See Access the Oracle ILOM CLI (NET MGT Port).

  2. Type.
    -> show / -a -l 4 -o table alarm_status
    Target              | Property               | Value 
    --------------------+------------------------+----------
    /SYS/MB/V_ECB       | alarm_status           | cleared 
    /SYS/MB/V_3.3VMain  | alarm_status           | cleared 
    /SYS/MB/            | alarm_status           | cleared 
     V_3.3VMainOK       |                        | 
    /SYS/MB/V_3.3VStby  | alarm_status           | minor 
    .
    .
    .
    /SYS/FAN3/PRSNT     | alarm_status           | cleared 
    /SYS/FAN3/TACH      | alarm_status           | cleared 
    /SYS/FAN3/FAULT     | alarm_status           | cleared 
    ->
  3. Look in the Value column for minor, major, or critical.

    For example, minor. For more information about alarm states, see Oracle ILOM Target Alarm States.

  4. Look in the same row under the Target column, to find the Oracle ILOM sensor target.

    For example, /SYS/MB/V_3.3VStby.

  5. Display the value of the sensor target.
    -> show target value

    where target is the Oracle ILOM target for the sensor from Step 4. For example:

    -> show /SYS/MB/V_3.3VStby value
     /SYS/MB/V_3.3VStby
         Properties:
             value = 3.490 Volts
    ->
  6. Record the target and value.

    For example, /SYS/MB/V_3.3VStby and 3.490 volts.

  7. Determine the sensor type.

    See Determine Oracle ILOM Sensor Target Types.

Related Information