Install the FIM

This is a cold-service procedure that must be performed by qualified service personnel. Power down the server completely before performing this procedure.

  1. Attach an antistatic wrist strap to your wrist, and then to a metal area on the chassis.

    See Prevent ESD Damage.

  2. Unpack the replacement FIM and place it on an antistatic mat.
  3. Connect the FIM cable to the replacement FIM assembly.

    See Remove the FIM.

  4. Carefully lower the FIM assembly into the chassis, position it over the Phillips screw in the server chassis, and slide it forward so all the LEDs, USB connectors, and Power On button fit into place on the server front panel.
  5. Tighten the Phillips screw to secure the FIM assembly to the server chassis.
  6. Position the storage drive cage cover over the server storage drive cage so that it over hangs the front of the disk drive cage by about 1/4 inch.
  7. Install the six Phillips screws to secure the cover to the server.

    There are three Phillips screws on each side of the storage drive cage.

  8. Close the server fan door.
  9. Return the server to operation.

    See Returning the Server to Operation.