El switch tiene varios subsistemas, y cada uno usa voltajes de energía diferentes de las fuentes de alimentación. Puede visualizar los diferentes niveles de energía suministrados al switch, además de los umbrales de eventos de esa energía.
-> show /SYS/MB/V_+1V0 /SYS/MB/V_+1V0 Properties: type = Voltage ipmi_name = MB/V_+1V0 class = Threshold Sensor value = 0.983 Volts upper_nonrecov_threshold = 1.068 Volts upper_critical_threshold = 1.058 Volts upper_noncritical_threshold = 1.049 Volts lower_noncritical_threshold = 0.941 Volts lower_critical_threshold = 0.931 Volts lower_nonrecov_threshold = 0.921 Volts alarm_status = cleared ->
-> show /SYS/MB/V_+1V2 /SYS/MB/V_+1V2 Properties: type = Voltage ipmi_name = MB/V_+1V2 class = Threshold Sensor value = 1.179 Volts upper_nonrecov_threshold = 1.284 Volts upper_critical_threshold = 1.274 Volts upper_noncritical_threshold = 1.264 Volts lower_noncritical_threshold = 1.137 Volts lower_critical_threshold = 1.127 Volts lower_nonrecov_threshold = 1.117 Volts alarm_status = cleared ->
-> show -d properties /SYS/MB/V_+1V5 /SYS/MB/V_+1V5 Properties: type = Voltage ipmi_name = MB/V_+1V5 class = Threshold Sensor value = 1.474 Volts upper_nonrecov_threshold = 1.676 Volts upper_critical_threshold = 1.646 Volts upper_noncritical_threshold = 1.578 Volts lower_noncritical_threshold = 1.421 Volts lower_critical_threshold = 1.352 Volts lower_nonrecov_threshold = 1.323 Volts alarm_status = cleared ->
-> show -d properties /SYS/MB/V_+1V8 /SYS/MB/V_+1V8 Properties: type = Voltage ipmi_name = MB/V_+1V8 class = Threshold Sensor value = 1.823 Volts upper_nonrecov_threshold = 1.921 Volts upper_critical_threshold = 1.911 Volts upper_noncritical_threshold = 1.891 Volts lower_noncritical_threshold = 1.705 Volts lower_critical_threshold = 1.686 Volts lower_nonrecov_threshold = 1.676 Volts alarm_status = cleared ->
-> show -d properties /SYS/MB/V_+2V5 /SYS/MB/V_+2V5 Properties: type = Voltage ipmi_name = MB/V_+2V5 class = Threshold Sensor value = 3.660 Volts upper_nonrecov_threshold = 2.671 Volts upper_critical_threshold = 2.652 Volts upper_noncritical_threshold = 2.632 Volts lower_noncritical_threshold = 2.379 Volts lower_critical_threshold = 2.359 Volts lower_nonrecov_threshold = 2.340 Volts alarm_status = critical ->
-> show -d properties /SYS/MB/V_+3V3 /SYS/MB/V_+3V3 Properties: type = Voltage ipmi_name = MB/V_+3V3 class = Threshold Sensor value = 3.256 Volts upper_nonrecov_threshold = 3.510 Volts upper_critical_threshold = 3.490 Volts upper_noncritical_threshold = 3.471 Volts lower_noncritical_threshold = 3.139 Volts lower_critical_threshold = 3.120 Volts lower_nonrecov_threshold = 3.101 Volts alarm_status = cleared ->
-> show -d properties /SYS/MB/V_+3V3_STDBY /SYS/MB/V_+3V3_STDBY Properties: type = Voltage ipmi_name = MB/V_+3V3_STDBY class = Threshold Sensor value = 3.246 Volts upper_nonrecov_threshold = 3.510 Volts upper_critical_threshold = 3.490 Volts upper_noncritical_threshold = 3.471 Volts lower_noncritical_threshold = 3.139 Volts lower_critical_threshold = 3.120 Volts lower_nonrecov_threshold = 3.101 Volts alarm_status = cleared ->
Visualizar el estado de una fuente de alimentación (CLI de Oracle ILOM)
Visualizar detalles de las fuentes de alimentación (CLI de Oracle ILOM)
Visualizar los estados de energía de entrada de una fuente de alimentación (CLI de Oracle ILOM)
Visualizar las propiedades generales de energía del switch (CLI de Oracle ILOM)
Visualizar información sobre las fuentes de alimentación (CLI de Oracle ILOM)
Visualizar la información de energía de la batería (CLI de Oracle ILOM)
Visualizar la información de energía del chip del switch IB (CLI de Oracle ILOM)
Visualizar la información de energía de los HCA (CLI de Oracle ILOM)
Visualizar información de energía de MBOM (CLI de Oracle ILOM)