Environmental Events
The following table lists environmental events.
|
|
SNMP Trap:
sunHwTrapTempFatalThresholdExceeded
Oracle ILOM Event Message:
Lower fatal threshold exceeded
Severity and Description:
Critical; A temperature sensor has reported that its value has gone
above an upper fatal threshold setting or below a lower fatal
threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/PS[0-1]/T_OUT
/SYS/PS[0-1]/T_IN
/SYS/MB/T_IN_SLOT[1-3]
/SYS/MB/T_OUT_SLOT[1-3]
|
SNMP Trap:
sunHwTrapTempFatalThresholdDeasserted
Oracle ILOM Event Message:
Lower fatal threshold no longer exceeded
Severity and Description:
Informational; A temperature sensor has reported that its value has
gone below an upper fatal threshold setting or above a lower fatal
threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/PS[0-1]/T_OUT
/SYS/PS[0-1]/T_IN
/SYS/MB/T_IN_SLOT[1-3]
/SYS/MB/T_OUT_SLOT[1-3]
|
SNMP Trap:
sunHwTrapTempCritThresholdExceeded
Oracle ILOM Event Message:
Upper critical threshold exceeded
Severity and Description:
Critical; A temperature sensor has reported that its value has gone
above an upper critical threshold setting or below a lower critical
threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/PS[0-1]/T_OUT
/SYS/PS[0-1]/T_IN
/SYS/MB/T_IN_SLOT[1-3]
/SYS/MB/T_OUT_SLOT[1-3]
|
SNMP Trap:
sunHwTrapTempCritThresholdDeasserted
Oracle ILOM Event Message:
Upper critical threshold no longer exceeded
Severity and Description:
Informational; A temperature sensor has reported that its value has
gone below an upper critical threshold setting or above a lower
critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/PS[0-1]/T_OUT
/SYS/PS[0-1]/T_IN
/SYS/MB/T_IN_SLOT[1-3]
/SYS/MB/T_OUT_SLOT[1-3]
|
SNMP Trap:
sunHwTrapTempFatalThresholdExceeded
Oracle ILOM Event Message:
Lower fatal threshold exceeded
Severity and Description:
Critical; A temperature sensor has reported that its value has gone
above an upper fatal threshold setting or below a lower fatal
threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/T_AMB
|
SNMP Trap:
sunHwTrapTempFatalThresholdDeasserted
Oracle ILOM Event Message:
Lower fatal threshold no longer exceeded
Severity and Description:
Informational; A temperature sensor has reported that its value has
gone below an upper fatal threshold setting or above a lower fatal
threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/T_AMB
|
|