Go to main content

Oracle® Server X8-2 Service Manual

Exit Print View

Updated: January 2021
 
 

Power Unit Components

The following table lists the power unit components.

Component Name (Oracle ILOM CLI Targets)
IPMI Type
Description
Values (if applicable)
/SYS/PS[0-1]
FRU
Power supply FRU
/SYS/PS[0-1]/PRSNT
Discrete sensor
Power supply is present.
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/PS[0-1]/STATE
Discrete sensor
Multistate, power supply sensor type, per IPMI
Presence detected
Failure detected
Predictive failure
Power supply input lost
Power supply input lost or out-of-range
Power supply input out-of-range
Configuration error
/SYS/PS[0-1]/P_IN
Power sensor
Input power draw
Watts
/SYS/PS[0-1]/P_OUT
Power sensor
Output power
Watts
/SYS/PS[0-1]/V_IN
Voltage sensor
Input voltage
Volts
/SYS/PS[0-1]/V_12V
Voltage sensor
12V output voltage
Volts
/SYS/PS[0-1]/V_12V_STBY
Voltage sensor
12V standby output voltage
Volts
/SYS/PS[0-1]/T_IN
Temperature sensor
PSU input temperature
Degrees Celsius
/SYS/PS[0-1]/T_OUT
Temperature sensor
PSU output temperature
Degrees Celsius

Related Information