Go to main content

Oracle® Server X8-2 Service Manual

Exit Print View

Updated: January 2021
 
 

Serial Management Port

The serial management connector, labeled SER MGT, is an RJ-45 connector that can be accessed from the back panel. This port is the default connection to the server Oracle ILOM SP. Use this port only for server management.

Table 6  Default Serial Connections for Serial Port
Parameter
Setting
Connector
SER MGT
Rate
9600 baud
Parity
None
Stop bits
1
Data bits
8

The following figure and table describe the SER MGT port pin signals.

image:Figure showing the pinouts on the serial management port. Table 7  Serial Management Port Signals
Pin
Signal Description
Pin
Signal Description
1
Request to Send
5
Ground
2
Data Terminal Ready
6
Receive Data
3
Transmit Data
7
Data Set Ready
4
Ground
8
Clear to Send

If you need to connect to the SER MGT port using a cable with either a DB-9 or a DB-25 connector, follow the pin descriptions in the tables to create a crossover adapter appropriate for your serial connection.

Table 8  RJ-45 to DB-9 Adapter Crossover Wiring Reference
Serial Port (RJ-45 Connector)
DB-9 Adapter
Pin
Signal Description
Pin
Signal Description
1
RTS
8
CTS
2
DTR
6
DSR
3
TXD
2
RXD
4
Signal Ground
5
Signal Ground
5
Signal Ground
5
Signal Ground
6
RXD
3
TXD
7
DSR
4
DTR
8
CTS
7
RTS
Table 9  RJ-45 to DB-25 Adapter Crossover Wiring Reference
Serial Port (RJ-45 Connector)
DB-25 Adapter
Pin
Signal Description
Pin
Signal Description
1
RTS
5
CTS
2
DTR
6
DSR
3
TXD
3
RXD
4
Signal Ground
7
Signal Ground
5
Signal Ground
7
Signal Ground
6
RXD
2
TXD
7
DSR
20
DTR
8
CTS
4
RTS

Related Information