Remove the replacement fan module from its packaging and place it on an
antistatic mat.
-
With the server top cover removed, position the replacement fan module into
the server.
The fan modules are keyed to ensure that they are installed in the correct
orientation.
-
Press down on the fan module and apply firm pressure to fully seat the fan
module.
-
Verify that the fan module status indicator (LED) that aligns with the
replaced fan module is extinguished.
-
Install the server top cover.
See Install the Server Top Cover.
-
Verify that the Top Fan Fault LED on the front of the server and the
Fault-Service Required LEDs on the front and back of the server are
extinguished.
See Troubleshooting Using the Server Front and Back Panel Status Indicators for more information about identifying and
interpreting system indicators.
-
Consider your next step:
-
If you installed the fan module as part of another procedure, return
to that procedure.
-
Otherwise, return the server to operation. See Returning the Server to Operation.