Power On the Server

As soon as the power cords are connected, Standby power is applied. In Standby power mode:

  • The System OK LED on the server front panel blinks slowly.

  • The SP OK LED indicator is steady on.

  • The AC power supply LED indicator lights are steady on.

    Depending on the firmware configuration, the system might boot. If it does not boot, perform the following procedure.

  • Power on the server to Main power mode by performing one of the following actions:
    • Press the On/Standby button on the front bezel.
    • Log in to the Oracle ILOM web interface, click Host Management → Power Control and select Power On from the Select Action list.
    • Log in to the Oracle ILOM command-line interface (CLI), and type the following command at the Oracle ILOM prompt:
      -> start /System
      

      When the server is powered on to Main power mode and the power-on self-test (POST) code checkpoint tests have completed, the green System OK LED status indicator on the front panel of the server lights and remains lit.