Connect Power to the Fabric Interconnect F1-15

The Fabric Interconnect F1-15's power supplies are located on the front of the chassis, and the power plugs are on the rear of the chassis as shown in Fabric Interconnect F1-15 Power Supplies for Connecting to AC Facility Power.


Caution

Caution  - Verify that your AC power source, as well as any equipment installed between the power source and the Fabric Interconnect (such as surge suppressors, plug bars, and so on) meet these requirements: – 100 - 127 / 200 - 240 V AC – 12 - 7.68 A – 47 - 63 Hz – 1220 W (maximum)


To connect Oracle Fabric Interconnect F1-15 to facility power, follow this procedure:

  1. Connect the dual power supplies to an AC power source. See Fabric Interconnect F1-15 Power Supplies for Connecting to AC Facility Power.

    Figure 57  Fabric Interconnect F1-15 Power Supplies for Connecting to AC Facility Power


    image:Figure shows two power supply connectors at the top left and right corners of the chassis.
  2. On the opposite side of Oracle Fabric Interconnect, simultaneously switch all power supplies to the “On” position.