Remove the RJ-45 Coupler Panel

  1. To avoid any lost connections or frozen operations, stop all applications currently running or scheduled to run.
  2. Follow safety and ESD precautions.

    See Safety and ESD Precautions.

  3. If any external cables are connected to the coupler panel:
    1. Record the connection locations for all external cables connected to the coupler panel.

      Customer cabling identifiers are specific to their modular systems and are not labeled at the factory. In contrast, factory cables are labeled with connection information.

    2. Disconnect all external cables.
  4. Using a No. 3 Phillips screwdriver, remove the four screws holding the coupler panel to the frame.
  5. Carefully pull out the coupler panel.
  6. Disconnect the internal cables from the coupler panel.
  7. Install the replacement coupler panel.

    See Install the RJ-45 Coupler Panel.