Install the Left LED Indicator Module

  1. Install the left LED indicator module.
    1. Push the LED indicator module and cable through the left LED housing on the server front panel [1].

      If necessary, use a piece of capping tape to secure the cable to the side of the disk cage assembly.


      Note -  Cable part number 7064122 is required for the left LED indicator module.

      image:Figure showing the installation of the left LED indicator module.
    2. Insert and tighten the two No. 2 Phillips screws to secure the LED indicator module to the server front panel [2].
  2. Gently lift the disk cage assembly and set it into the server chassis [1].

    Slightly push the disk cage assembly into the server chassis to ensure that the disk cage screw holes are correctly aligned with the server chassis.


    image:Figure showing the installation of the disk cage assembly in the server chassis.
  3. Reconnect the left LED indicator module cable and the right LED/USB indicator module cable to the motherboard [2 and 3].
  4. Reconnect all cables to the front storage drive backplane.

    See the procedures for your storage drive configuration in Servicing the Storage Drive Backplanes.

  5. Install the fan modules in the server.

    See Install a Fan Module.

  6. Install the four No. 2 Phillips screws (two on each side of the chassis) that secure the disk cage assembly to the server chassis.
    image:Figure showing the installation of the disk cage assembly screws.
  7. Install the server fan assembly door.

    See Install the Fan Assembly Door.

  8. Return the server to operation.
    1. Install the server top cover.

      See Install the Server Top Cover.

    2. Return the server to the normal rack position.

      See Return the Server to the Normal Rack Position.

    3. Reconnect the power cords to the power supplies, and power on the server.

      See Reconnect Power and Data Cables and Power On the Server. Verify that the power supply AC OK LED is lit.