Go to main content

Oracle® Exadata Storage Server X6-2 High Capacity Service Manual

Exit Print View

Updated: January 2018
 
 

Install the Storage Drive Backplane

  1. Lower the storage drive backplane into the server, and position it to engage the standoff hooks [1].
    image:Figure showing the storage drive backplane for a twelve-drive system being installed in the server.
  2. Using a No. 2 Phillips screwdriver, install and tighten the right-side spring-mounted screw to secure the storage drive backplane to the chassis [2].
  3. Reconnect the cables to the storage drive backplane.
    1. Reconnect the auxiliary signal cable and the power cable to the storage drive backplane [3].

      Use the following cable part number table to ensure proper cable connections:

      Cable Part Number
      Description
      7079291
      Auxiliary signal cable
      7086654
      Power cable
    2. Reconnect the SAS cable to the storage drive backplane from the rear-mounted storage drives, and the two SAS cables to the storage drive backplane from the Sun Storage 12 Gb SAS PCIe RAID HBA [4].

      To ensure proper SAS cable connections, see Install SAS Storage Drive Cables.

  4. Return the server to operation.
    1. Install the fan assembly door top cover.

      See Install the Fan Assembly Door.

    2. Install the fan modules and close the fan assembly door.

      See Install a Fan Module.

    3. Install all storage drives into the storage drive cage.

      See Install a Storage Drive.

    4. Return the server to the normal rack position.

      See Return the Server to the Normal Rack Position.

    5. Reconnect the power cords to the power supplies, and power on the server.

      See Reconnect Power and Data Cables and Power On the Server. Verify that the AC OK LED is lit.


    Note -  IMPORTANT: When the disk backplane is replaced, the key identity properties (KIP) of the disk backplane is programmed by Oracle ILOM to contain the same KIP as the other quorum member components. If you have removed other quorum member components, you might need to manually program the product serial number (PSN) into the new disk backplane. For more information, refer to FRU Key Identity Properties (KIP) Automated Update.