Go to main content

Oracle® Exadata Storage Server X6-2 High Capacity Service Manual

Exit Print View

Updated: January 2018
 
 

Remove the Server From the Rack


Caution

Caution  -  The server weighs approximately 63 pounds (28.5 kg). Two people are required to unmount and carry the chassis.


  1. Disconnect all the cables and power cords from the server.
  2. Remove the cable management arm (CMA).

    For instructions for removing the CMA, see the Remove the Cable Management Arm in Oracle Exadata Storage Server X6-2 High Capacity Installation Guide.

  3. Extend the server to the maintenance position.

    See Extend the Server to the Maintenance Position.

  4. From the front of the server, pull the green slide-rail release tabs toward the front of the server, and pull the server out of the rack until is free of the rack rails [1 and 2].

    A slide-rail release tab is located on each slide-rail.


    image:Figure showing the server being removed from the chassis.
  5. Set the server on a sturdy work surface.