Go to main content

Oracle® Exadata Storage Server X6-2 High Capacity Service Manual

Exit Print View

Updated: January 2018
 
 

Index

A

activity indicatorindex iconServer System-Level Status Indicators
add-in cards
configuration utilities in Legacy BIOS Boot Modeindex iconConfiguration Utilities for Add-In Cards
configuration utilities in UEFI BIOS Boot Modeindex iconConfiguration Utilities for Add-In Cards
Advanced BIOS screenindex iconBIOS Advanced Menu Selections
antistatic
matindex iconElectrostatic Discharge Safety
measures
applyingindex iconTake Antistatic Measures
wrist strapindex iconElectrostatic Discharge Safety
antistatic measures
removingindex iconRemove Antistatic Measures
attaching devices to serverindex iconAttaching Devices to the Server

B

battery
descriptionindex iconField-Replaceable Units
installingindex iconInstall the Battery
removingindex iconRemove the Battery
BIOS
configuring serial port sharingindex iconConfiguring Serial Port Sharing
Ethernet ports booting priorityindex iconEthernet Port Boot Order
BIOS boot mode, switching between Legacy BIOS and UEFI modesindex iconSwitching Between Legacy BIOS and UEFI Boot Modes
BIOS factory defaults, verifyingindex iconVerify BIOS Factory Default Settings
BIOS Setup Utility
accessingindex iconAccess BIOS Setup Utility Menus
Advanced screenindex iconBIOS Advanced Menu Selections
boot modeindex iconSelecting Legacy BIOS or UEFI Boot Mode
Boot screenindex iconBIOS Boot Menu Selections
Exit screenindex iconBIOS Exit Menu Selections
exiting fromindex iconExit BIOS Setup Utility
function keysindex iconBIOS Key Mappings
IO screenindex iconBIOS IO Menu Selections
legacy boot modeindex iconSelecting Legacy BIOS or UEFI Boot Mode
Main screenindex iconBIOS Main Menu Selections
menus, accessingindex iconAccess BIOS Setup Utility Menus
navigating menu optionsindex iconNavigate BIOS Setup Utility Menus
service processor network settingsindex iconConfigure SP Network Settings
setup screens summaryindex iconBIOS Setup Utility Menus
shortcut key sequencesindex iconBIOS Key Mappings
TPM supportindex iconConfigure TPM Support
UEFI boot modeindex iconSelecting Legacy BIOS or UEFI Boot Mode
UEFI-compliant, descriptionindex iconUsing UEFI
board componentsindex iconSystem Chassis Components
boot device, selectingindex iconSelect the Boot Device
boot drive
LEDsindex iconStorage and Boot Drive Indicators
boot mode
preserving settings when switching modesindex iconSwitching Between Legacy BIOS and UEFI Boot Modes
selectingindex iconSelect Legacy BIOS or UEFI BIOS Boot Mode
button
fault remindindex iconRemove a Processor
buttons
Power
index iconPower On the Server
index iconPower Down the Server for Immediate Shutdown Using the Power Button

C

cable part number
auxiliary signal cableindex iconInstall the Storage Drive Backplane
left LED indicator module cableindex iconInstall the Left LED Indicator Module
power cable, centerindex iconInstall the Storage Drive Backplane
power cable, rightindex iconInstall the Storage Drive Backplane
right LED/USB indicator module cableindex iconInstall the Right LED/USB Indicator Module
SAS cablesindex iconInstall SAS Storage Drive Cables
cables
connectingindex iconReconnect Power and Data Cables
disconnectingindex iconDisconnect Cables From the Server
cabling the serverindex iconAttach Devices to the Server
chassis componentsindex iconSystem Chassis Components
chassis serial number, locatingindex iconLocating the Chassis Serial Number
components and nomenclatureindex iconSystem Chassis Components
connecting devices to serverindex iconAttaching Devices to the Server
connector locationsindex iconAttaching Devices to the Server
controls, front panelindex iconAbout Controls and Connectors
cooling unit componentsindex iconCooling Unit Components
crossover pinouts for SER MGT portindex iconSerial Management Port Signals

D

default boot modeindex iconSelect Legacy BIOS or UEFI BIOS Boot Mode
diagnosing
hardware faultsindex iconTroubleshooting and Diagnostic Information
DIMMs
descriptionindex iconField-Replaceable Units
fault LEDs
inconsistencies with BIOSindex iconInconsistencies Between DIMM Fault Indicators and the BIOS Isolation of Faulty DIMMs
Fault Remind buttonindex iconUsing the Storage Server Fault Remind Button
identifying a faulty DIMMindex iconIdentify and Remove a Faulty DIMM
installingindex iconInstall a DIMM
physical layoutindex iconDIMM and Processor Physical Layout
population rulesindex iconDIMM Population Rules
removingindex iconIdentify and Remove a Faulty DIMM
supported configurationsindex iconDIMM Population Rules
disk backplane componentsindex iconDisk Backplane Components
disk componentsindex iconHard Disk Drive Components
disk drives  Seeindex icon drive
drive
descriptionindex iconField-Replaceable Units
hot-pluggingindex iconStorage Drives Hot-Plug Conditions
identificationindex iconRemove a Storage Drive
installingindex iconInstall a Storage Drive
latch release buttonindex iconRemove a Storage Drive
removingindex iconRemove a Storage Drive

E

electrostatic discharge
preventionindex iconTake Antistatic Measures
safety precautionsindex iconElectrostatic Discharge Safety
entity presence eventsindex iconEntity Presence Events
environmental eventsindex iconEnvironmental Events
Ethernet cables, connectingindex iconAttach Devices to the Server
Ethernet ports
booting priority
index iconEthernet Port Boot Order
index iconEthernet Port Boot Order
device and driver namingindex iconEthernet Port Boot Order and Device Naming
pinoutindex icon10-GbE Port Signals
Exit BIOS screenindex iconBIOS Exit Menu Selections
exploded view of serverindex iconIllustrated Parts Breakdown
external cables, connectingindex iconAttach Devices to the Server

F

fan assembly door
installingindex iconInstall the Fan Assembly Door
removingindex iconRemove the Fan Assembly Door From the Server
fan eventsindex iconFan Events
fan module
descriptionindex iconField-Replaceable Units
installingindex iconInstall a Fan Module
removingindex iconRemove a Fan Module
Fault Remind button
locationindex iconUsing the Storage Server Fault Remind Button
usingindex iconUsing the Storage Server Fault Remind Button
fault remind buttonindex iconRemove a Processor
firmware componentsindex iconSystem Chassis Components
function keys within BIOS Setup Utilityindex iconBIOS Key Mappings

G

Gigabit Ethernet portsindex iconGigabit Ethernet Ports
pinoutindex icon10-GbE Port Signals

H

hard disk drive componentsindex iconHard Disk Drive Components
hard disk drive eventsindex iconHard Disk Drive Events
hard drives  Seeindex icon drive
hardware faults
diagnosingindex iconTroubleshooting and Diagnostic Information
hot-plugging drivesindex iconStorage Drives Hot-Plug Conditions

I

illustrated parts breakdownindex iconIllustrated Parts Breakdown
installing
batteryindex iconInstall the Battery
DIMMsindex iconInstall a DIMM
driveindex iconInstall a Storage Drive
fan assembly doorindex iconInstall the Fan Assembly Door
fan moduleindex iconInstall a Fan Module
LED indicator module (left)index iconInstall the Left LED Indicator Module
LED/USB indicator module (right)index iconInstall the Right LED/USB Indicator Module
motherboard assemblyindex iconInstall the Motherboard Assembly
Oracle Storage 12 Gb/s SAS PCIe RAID HBA cardindex iconInstall the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card
PCIe cardsindex iconInstall a PCIe Card
power supplyindex iconInstall a Power Supply
processorsindex iconInstall a Processor
server into rackindex iconReinstall the Server in the Rack
server top coverindex iconInstall the Server Top Cover
twelve-drive storage drive backplaneindex iconInstall the Storage Drive Backplane
USB flash driveindex iconInstall the Internal USB Flash Drive
IO allocation
enabling and disabling resourcesindex iconConfigure I/O Resource Allocation
IO BIOS screenindex iconBIOS IO Menu Selections
IP address, settingindex iconConfigure SP Network Settings
IPMI typeindex iconMonitoring System Components

L

latch release button, driveindex iconRemove a Storage Drive
LED indicator module (left)
installingindex iconInstall the Left LED Indicator Module
removingindex iconRemove the Left LED Indicator Module
LED/USB indicator module (right)
installingindex iconInstall the Right LED/USB Indicator Module
removingindex iconRemove the Right LED/USB Indicator Module
LED/USB indicator modules
replacingindex iconServicing the Front LED/USB Indicator Modules
LEDs
boot driveindex iconStorage and Boot Drive Indicators
power supply
index iconRemove a Power Supply
index iconServicing Power Supplies
index iconPower Supply Status Indicators
storage driveindex iconStorage and Boot Drive Indicators
system statusindex iconServer System-Level Status Indicators
Legacy BIOS Boot Mode
selectingindex iconSelecting Legacy BIOS or UEFI Boot Mode
switching between UEFI Boot Modeindex iconSwitching Between Legacy BIOS and UEFI Boot Modes
locating chassis serial numberindex iconLocating the Chassis Serial Number
Locator LED buttonindex iconServer System-Level Status Indicators

M

Main BIOS screenindex iconBIOS Main Menu Selections
memory device componentsindex iconMemory Device Components
memory eventsindex iconMemory Events
menus, BIOS Setup Utilityindex iconAccess BIOS Setup Utility Menus
motherboard assembly
installingindex iconInstall the Motherboard Assembly
LED/USB cablesindex iconRemove the Motherboard Assembly
removingindex iconRemove the Motherboard Assembly
replacingindex iconServicing the Motherboard Assembly

N

NET MGT port
pinout
index iconNetwork Management Port Signals
index iconNetwork Management Port
index iconNetwork Management Port Status Indicators
network settings, service processorindex iconConfigure SP Network Settings
Network Time Protocol (NTP)index iconInstall the Battery

O

operating system
supported by UEFI BIOSindex iconSelecting Legacy BIOS or UEFI Boot Mode
Option ROMs
enabling and disablingindex iconConfigure Option ROM Settings
legacy BIOS allocationindex iconLegacy Option ROM Allocation
minimizing resource exhaustionindex iconLegacy Option ROM Allocation
Oracle Integrated Lights Out Manager (Oracle ILOM)
key identity properties (KIP) for FRUID auto-update featureindex iconFRU Key Identity Properties (KIP) Automated Update
Oracle Storage 12 Gb/s SAS PCIe RAID HBA card
installingindex iconInstall the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card
replacingindex iconServicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card

P

PCIe cards
descriptionindex iconField-Replaceable Units
installingindex iconInstall a PCIe Card
removingindex iconRemove a PCIe Card
replacingindex iconServicing PCIe Cards
slot characteristicsindex iconPCIe Slot Locations
PCIe slot numberingindex iconPCIe Slot Locations
physical security eventsindex iconPhysical Security Events
pinout
Ethernet portsindex icon10-GbE Port Signals
Gigabit Ethernet portsindex icon10-GbE Port Signals
network management portindex iconNetwork Management Port Signals
RJ-45 to DB-25 crossover pinoutindex iconRJ-45 to DB-9 Adapter Crossovers Wiring Reference
serial management portindex iconSerial Management Port Signals
USB portindex iconUSB Port Signals
video connectorindex iconVideo Connector
ports
Ethernetindex iconGigabit Ethernet Ports
Gigabit Ethernetindex iconGigabit Ethernet Ports
network management (NET MGT)
index iconNetwork Management Port
index iconNetwork Management Port Status Indicators
serial management (SER MGT)index iconSerial Management Port
USBindex iconUSB Ports
videoindex iconVideo Connector
power
button
index iconPower On the Server
index iconPower Down the Server for Immediate Shutdown Using the Power Button
server onindex iconPower On the Server
standby power modeindex iconDisconnect Cables From the Server
power down server
emergencyindex iconPower Down the Server for Immediate Shutdown Using the Power Button
power eventsindex iconPower Events
power supply
descriptionindex iconField-Replaceable Units
installingindex iconInstall a Power Supply
LEDs
index iconRemove a Power Supply
index iconServicing Power Supplies
index iconPower Supply Status Indicators
removingindex iconRemove a Power Supply
power unit componentsindex iconPower Unit Components
power-on self-test (POST) code checkpoint testsindex iconServer System-Level Status Indicators
Power/OK indicatorindex iconServer System-Level Status Indicators
processor componentsindex iconProcessor Components
processor removal/replacement toolindex iconProcessor Removal and Replacement Tool
processor socket cover
installingindex iconRemove the Motherboard Assembly
removingindex iconRemove the Motherboard Assembly
processor(s)
physical layoutindex iconDIMM and Processor Physical Layout
processors
identifying faulty processorindex iconRemove a Processor
installingindex iconInstall a Processor
maximum DIMMs supportedindex iconDIMM Population Rules
removal/replacement toolindex iconProcessor Removal and Replacement Tool
removingindex iconRemove a Processor
replacingindex iconServicing Processors
PSU  Seeindex icon power supply

R

removing
antistatic measuresindex iconRemove Antistatic Measures
batteryindex iconRemove the Battery
DIMMsindex iconIdentify and Remove a Faulty DIMM
driveindex iconRemove a Storage Drive
fan assembly doorindex iconRemove the Fan Assembly Door From the Server
fan moduleindex iconRemove a Fan Module
LED indicator module (left)index iconRemove the Left LED Indicator Module
LED/USB indicator module (right)index iconRemove the Right LED/USB Indicator Module
motherboard assemblyindex iconRemove the Motherboard Assembly
PCIe cardsindex iconRemove a PCIe Card
power supplyindex iconRemove a Power Supply
processorsindex iconRemove a Processor
server top coverindex iconRemove the Server Top Cover
Sun Storage 12 Gb/s SAS PCIe RAID HBA cardindex iconRemove the Sun Storage 12 Gb/s SAS PCIe RAID HBA Card
twelve-drive storage drive backplaneindex iconRemove the Storage Drive Backplane
USB flash driveindex iconRemove the Internal USB Flash Drive
replacing
batteryindex iconServicing the Battery
DIMMsindex iconServicing the DIMMs
fan tray 0index iconServicing Fan Modules
LED/USB indicator modulesindex iconServicing the Front LED/USB Indicator Modules
motherboard assemblyindex iconServicing the Motherboard Assembly
power supplyindex iconServicing Power Supplies
processorsindex iconServicing Processors
SAS cablesindex iconServicing SAS Cables
server top coverindex iconInstall the Server Top Cover
storage drive backplanesindex iconServicing the Storage Drive Backplanes

S

safety
ESD precautionsindex iconElectrostatic Discharge Safety
precautionsindex iconSafety Precautions
symbolsindex iconSafety Symbols
SAS cables
replacingindex iconServicing SAS Cables
screens, BIOS Setup Utility
index iconAccess BIOS Setup Utility Menus
index iconBIOS Setup Utility Menus
serial management (SER MGT) port
pinoutindex iconSerial Management Port Signals
RJ-45 to DB-9 crossover pinoutindex iconRJ-45 to DB-9 Adapter Crossovers Wiring Reference
serial number, locatingindex iconLocating the Chassis Serial Number
serial port sharing, configuringindex iconConfiguring Serial Port Sharing
server
diagnosingindex iconTroubleshooting and Diagnostic Information
installing into rackindex iconReinstall the Server in the Rack
returning server to operationindex iconReturning the Server to Operation
troubleshootingindex iconTroubleshooting Server Component Hardware Faults
server top cover
installingindex iconInstall the Server Top Cover
removingindex iconRemove the Server Top Cover
server troubleshooting, information needed when contacting supportindex iconContacting Support
server, power onindex iconAccess BIOS Setup Utility Menus
service
preparing serverindex iconPreparing the Server for Component Replacement
service processor
network settings, configuringindex iconConfigure SP Network Settings
Service Required LEDindex iconServer System-Level Status Indicators
set commandindex iconInstall a Processor
shortcut key sequences in BIOS Setup Utilityindex iconBIOS Key Mappings
show commandindex iconInstall a Processor
shutting down the system
immediately, using Oracle ILOM CLIindex iconPower Down the Server for Immediate Shutdown Using the Oracle CLI
immediately, using Oracle ILOM web interfaceindex iconPower Down the Server for Immediate Shutdown Using the Oracle ILOM Web Interface
immediately, using the Power buttonindex iconPower Down the Server for Immediate Shutdown Using the Power Button
Simple Network Management Protocol (SNMP) Traps
generated by systemindex iconIdentifying SNMP Trap Messages
standby power
index iconDisconnect Cables From the Server
index iconPower Down the Server for Immediate Shutdown Using the Oracle ILOM Web Interface
index iconPower Down the Server for Immediate Shutdown Using the Oracle CLI
index iconPower Down the Server for Immediate Shutdown Using the Power Button
start commandindex iconPower On the Server
storage drive
LEDsindex iconStorage and Boot Drive Indicators
storage drive backplanes
replacingindex iconServicing the Storage Drive Backplanes
Sun Storage 12 Gb/s SAS PCIe RAID HBA card
removingindex iconRemove the Sun Storage 12 Gb/s SAS PCIe RAID HBA Card
support for productindex iconContacting Support
system board componentsindex iconSystem Board Components
system chassis componentsindex iconSystem Chassis Components
system components and nomenclatureindex iconMonitoring System Components
system firmware componentsindex iconSystem Firmware Components

T

technical supportindex iconContacting Support
tools required for serviceindex iconRequired Tools
troubleshooting
information needed when contacting supportindex iconContacting Support
overviewindex iconTroubleshooting With Diagnostic Tools
serverindex iconTroubleshooting Server Component Hardware Faults
Trusted Platform Module (TPM), configuring support forindex iconConfigure TPM Support
twelve-drive storage drive backplane
installingindex iconInstall the Storage Drive Backplane
removingindex iconRemove the Storage Drive Backplane

U

UEFI boot mode
advantages of usingindex iconUEFI Boot Mode Advantages
selectingindex iconSelecting Legacy BIOS or UEFI Boot Mode
supported operating systemsindex iconSelecting Legacy BIOS or UEFI Boot Mode
UEFI-compliant BIOS, descriptionindex iconUsing UEFI
USB flash drive
installingindex iconInstall the Internal USB Flash Drive
removingindex iconRemove the Internal USB Flash Drive
USB port
pinoutindex iconUSB Port Signals

V

video port
pinoutindex iconVideo Connector

W

weight of serverindex iconRemove the Server From the Rack