Documentation, Support, and Training
Understanding Administrative Commands
Monitoring the InfiniBand Fabric
Controlling the InfiniBand Fabric
Understanding Signal Routing Through the Switch
Understanding Switch Startup and Component Addition
Understanding ILOM on the Switch
Switching Between the ILOM Shell and the Linux Shell
Controlling ILOM Targets (CLI)
Upgrading the Switch Firmware Through ILOM (CLI)
Administering ILOM (Web Interface)
Access ILOM From the Web Interface
Monitoring ILOM Targets (Web Interface)
Controlling ILOM Targets (Web Interface)
Upgrading the Switch Firmware Through ILOM (Web Interface)
Understanding InfiniBand Cabling
Understanding Switch Specifications
Understanding the Installation
Installing the InfiniBand Software Stack
Verifying the InfiniBand Fabric
Understanding Service Procedures
Inspect the Power Supply Hardware
Inspect the Power Supply Connectors
Servicing the Fabric Cards and Fabric Card Fillers
Inspect the Fabric Card Chassis
Inspect the Fabric Card Retainer Bolts
Inspect the Fabric Card XBOW Connectors
Remove a Fabric Card or Fabric Card Filler
Install a Fabric Card or Fabric Card Filler
Servicing the InfiniBand Cables
Inspecting the InfiniBand Cables
InfiniBand Cable Identification
Inspect the InfiniBand Cable Hardware
Inspect the InfiniBand Cable Connectors
Inspect the Line Card Retainer Bolts
Inspect the Line Card XBOW Connectors
Inspect the Line Card CXP Connectors
Doing Supportive Software Tasks
Configure CMCs for Identical Addresses
Understanding Switch-Specific Commands
Note - Use the table in Component Addressing to determine the slot number or IPMB address of your component.
See the table in Servicing the CMCs.
# clia fruinfo IPMB_address 0
where IPMB_address is from Component Addressing.
The following example is the output for CMC 0:
# clia fruinfo 10 0 Pigeon Point Shelf Manager Command Line Interpreter 10: FRU # 0, FRU Info Common Header: Format Version = 1 Board Info Area: Version = 1 Language Code = 25 Mfg Date/Time = May 22 09:16:00 2009 (7042156 minutes since 1996) Board Manufacturer = Sun Microsystems Board Product Name = Sun Datacenter Switch DCS 648 - CMC board Board Serial Number = 0110SJC-0911CM0001 Board Part Number = 541-3807-02 FRU Programmer File ID = M9_CMC_FRU_541-3807-02_0110SJC-0911CM0001.txt Product Info Area: Version = 1 Language Code = 25 Manufacturer Name = Sun Microsystems Product Name = Sun Datacenter Switch DCS 648 - CMC board Product Part / Model# = 541-3807-02 Product Version = Rev 50 Product Serial Number = 0110SJC-0905CM0003 Asset Tag = none FRU Programmer File ID = M9_CMC_FRU_541-3807-02_0110SJC-0911CM0001.txt Multi Record Area: PICMG Board Point-to-Point Connectivity Record (ID=0x14) Version = 0 Record Type = 0xc0 OEM Defined Record Version = 2 PPS IPMB Topology Record (ID=0x05) Version = 0 #
Switch Reference, version command
Switch Reference, switchover command
Switch Reference, setlanconfig command
Switch Reference, user add command
Switch Reference, localaddress command