Host Diagnostic
Tasks and Applicable CLI Targets
Use the following table to help identify the applicable CLI
namespace targets for Oracle ILOM host diagnostic tasks.
For detailed information about host diagnostics, see the topics listed in the Related
Information section that appears after the table.
|
|
|
View or modify host diagnostic properties on an x86
server.
|
/HOST/diag state
-
enabled
-
disabled
-
extended
-
manual
-
set
Note -
To run and view diagnostics, launch the remote system
console from the web interface, and then restart the
server.
Note -
To issue the full CLI path for host diagnostics from the
CMM, append
/Servers/Blades/Blade_n
to the beginning of the /HOST/diag
target.
Note -
To issue the full CLI path for host diagnostics from the
FMM, append
/Servers/ComputeNodes/ComputeNode_n
to the beginning of the /HOST/diag
state target.
|
|
View or modify host diagnostic properties on a SPARC
server.
|
/HOST/diag
-
error_reset_level
-
error_reset_verbosity
-
hw_change_level
-
hw_change_verbosity
-
level
-
max
-
power_on_level
-
power_on_verbosity
-
trigger
-
verbosity
-
set
Note -
SPARC host diagnostic properties vary from system to
system. Use the Help command to
determine which host diag properties are supported on your
server. For example: help /HOST/diag
Note -
To issue the full CLI path for host diag from a
multi-domain SPARC server, append
/Servers/PDomains/PDomain_n
to the beginning of the /HOST/diag
target.
Note -
To run and view diagnostics, launch the remote system
console from the web interface, and then restart the
system.
|
|
View or modify SP diagnostic properties on M7 or T7 series
SPARC servers.
|
/SP/diag
-
default_level
-
hw_change_level
Note -
To run and view diagnostics, launch the remote console
from the web interface, and then restart the system.
|
|
|