System Power Usage Policy Tasks and Applicable CLI Targets

Use the following table to help identify the applicable CLI namespace targets for Oracle ILOM system power usage policy tasks and alert notification tasks.

The following table does not provide the full CLI path to the /SP target on all managed devices. For instance, to access the /SP target from either a multi-domain SPARC server, a blade system CMM, or a Netra FMM, append the applicable CLI properties to the beginning of the /SP target:

  • SPARC multi-domain server, where applicable, append: /Servers/PDomains/PDomain_n

  • Blade system CMM, where applicable, append: /Servers/Blades/Blade_n

  • Netra frame system FMM, where applicable, append: /Servers/ComputeNodes/ComputeNode_n


Note -  Not all power policy CLI targets are supported on all managed devices. Use the help command to view the namespeace targets supported on a managed device . For example,

help /SP/powermgmt -or- help /CMM/powermgmt


For detailed information about setting power usage policies and alert notifications in Oracle ILOM, see the topics listed in the Related Information section that appears after the table.

Power Policy Tasks
CLI Properties on Managed Device
User Role Required
Manage system component power from server SP. If applicable, set properties for alert notification thresholds and power budget.
/SP/powermgmt
  • actual_power

    permitted_power

    allocated_power

    available_power

  • threshold1|2=

  • /powerconf

  • /budget

  • Admin (a)

Manage blade system chassis power from CMM. If applicable, set properties for power supply redundancy and alert notification thresholds.
/CMM/powermgmt
  • actual_power

    permitted_power

    allocated_power

    available_power

    redundancy

    redundant_power

  • threshold1|2=

  • /powerconf

  • /advanced

  • Admin (a)

Related Information