| Skip Navigation Links | |
| Exit Print View | |
|
Sun Datacenter InfiniBand Switch 36 HTML Document Collection for Firmware Version 2.0 |
Network Management Connector and Pins
USB Management Connector and Pins
Preparing to Install the Switch
Suggested Tools for Installation
Antistatic Precautions for Installation
Verify Shipping Carton Contents
Install the Switch in the Rack
Verifying the InfiniBand Fabric
Understanding Routing Through the Switch
Understanding Administrative Commands
Administering the I4 Switch Chip
Controlling the I4 Switch Chip
Administering the Subnet Manager
Controlling the Subnet Manager
Administering the InfiniBand Fabric
Monitoring the InfiniBand Fabric
Controlling the InfiniBand Fabric
Configuring the Fabric Director Node List
Partitioning the InfiniBand Fabric
Understanding Oracle ILOM on the Switch
Understanding Oracle ILOM Targets
Installing the Oracle ILOM Firmware
Acquire the Oracle ILOM Firmware Version 1.1.3
Install the Oracle ILOM Firmware Version 1.1.3
Administering Oracle ILOM (CLI)
Accessing Oracle ILOM From the CLI
Switching Between the Oracle ILOM Shell and the Linux Shell
Monitoring Oracle ILOM Targets (CLI)
Controlling Oracle ILOM Targets (CLI)
Upgrading the Switch Firmware Through Oracle ILOM (CLI)
Administering Oracle ILOM (Web)
Access Oracle ILOM From the Web Interface
Monitoring Oracle ILOM Targets (Web)
Controlling Oracle ILOM Targets (Web)
Upgrade the Switch Firmware (Web)
Accessing the Rear Panel Diagram
Accessing Status Pane Information
Monitoring Parameters and Status
Administering Oracle ILOM (SNMP)
Monitoring Oracle ILOM Targets (SNMP)
Controlling Oracle ILOM Targets (SNMP)
Display the Sensor States (IPMI)
Display the Sensor Information (IPMI)
Display the System Event Log (IPMI)
Display FRU ID Information (IPMI)
Display Switch Status LED States (IPMI)
Disable the Locator LED (IPMI)
Understanding Oracle ILOM Commands
Understanding Service Procedures
Antistatic Precautions for Service
Remove the Switch From the Rack
Understanding Hardware Commands
Linux Shells for Hardware Commands
Understanding InfiniBand Commands
Linux Shells for InfiniBand Commands
Understanding the SUN-DCS-IB-MIB MIB OIDs
Understanding the SUN-FABRIC-MIB MIB OIDs
Understanding the SUN-HW-TRAP-MIB MIB OIDs
Understanding the SUN-ILOM-CONTROL-MIB MIB OIDs
Understanding the SUN-PLATFORM-MIB MIB OIDs
Understanding Cabling
cd Command
Exchange Master Fabric Director Status
Change the Administrator Password
Administering the Chassis
Controlling the Chassis
Display Chassis FRU ID
Check Chassis Status LEDs
Display Internal Temperatures
Check Board-Level Voltages
Display Switch Environmental and Operational Data
Display Switch Environmental and Operational Data
Display Fan Status
Display Fan Status
Check Chassis Status LEDs
Check Fan Status LEDs
Check Link Status LEDs
Check Network Management Port Status LEDs
Check Power Supply Status LEDs
Display Link Status
Display Switch Chip Port Status
Display Power Supply Status
Display Switch Chip Boot Status
checktopomax Command
Clear Data and Error Counters
Clear Data and Error Counters
Clear the Oracle ILOM Event Log (CLI)
Clear the Oracle ILOM Event Log (SNMP)
Clear the Oracle ILOM Event Log (Web)
Clear the Subnet Manager Management Key
Acquire the Switch Firmware Package (CLI)
Add an Oracle ILOM User Account (CLI)
Add SNMP Service Communities (CLI)
Add SNMP Service User Accounts (CLI)
Back Up the Configuration (CLI)
Change an Oracle ILOM User’s Password and or Role (CLI)
Clear the Oracle ILOM Event Log (CLI)
Configure the DNS Client (CLI)
Configure the SMTP Client (CLI)
Create a Snapshot of the Switch State (CLI)
Delete an Oracle ILOM User Account (CLI)
Delete SNMP Service Communities (CLI)
Delete SNMP Service User Accounts (CLI)
Disable Alerts (CLI)
Disable the HTTP Service (CLI)
Disable the HTTPS Service (CLI)
Disable the IPMI Service (CLI)
Set the Remote Log Hosts (CLI)
Disable the SNMP Service (CLI)
Display the Aggregate Sensors State (CLI)
Display the Alert Properties (CLI)
Display Board-Level Voltages (CLI)
Display the CLI Session Timeout (CLI)
Display the Date (CLI)
Display the DNS Client Status (CLI)
Display Fan Status (CLI)
Display Fan Status (CLI)
Get Help on an Oracle ILOM Command (CLI)
Display System Identification Properties (CLI)
Display the HTTP Service Status (CLI)
Display the HTTPS Service Status (CLI)
Display the Oracle ILOM Event Log (CLI)
Display the Oracle ILOM Sessions (CLI)
Display the Oracle ILOM User Accounts (CLI)
Display the Firmware Version (CLI)
Display Internal Temperatures (CLI)
Display the IPMI Service Status (CLI)
Display the Remote Log Hosts (CLI)
Display the Network Management Configuration (CLI)
Display the NTP Servers (CLI)
Verifying Other Aspects With Oracle ILOM (CLI)
Display Power Supply FRU ID (CLI)
Display Power Supply Status (CLI)
Checking the Status of Services (CLI)
Display the SNMP Service Communities (CLI)
Display the SNMP Service Status (CLI)
Display the SNMP User Accounts (CLI)
Display the SSL Certificates (CLI)
Display Switch FRU ID (CLI)
Display Switch Status LEDs States (CLI)
Display System Identification Properties (CLI)
Get Help on an Oracle ILOM Target Property (CLI)
Download SNMP Service MIBs (CLI)
Enable Alerts to Send Email Alerts (CLI)
Enable Alerts to Send PETs (CLI)
Enable Alerts to Send SNMP Traps (CLI)
Enable the HTTP Service (CLI)
Enable the HTTPS Service (CLI)
Enable the IPMI Service (CLI)
Set the Remote Log Hosts (CLI)
Enable the SNMP Service (CLI)
CLI Overview
Managing HTTP Services (CLI)
Managing HTTPS Services (CLI)
Managing IPMI Services (CLI)
Managing Other Aspects With Oracle ILOM (CLI)
Managing SNMP Services (CLI)
Modify SNMP Service Communities (CLI)
Modify SNMP Service User Accounts (CLI)
Performing Daily Tasks (CLI)
Performing General Tasks on Oracle ILOM Targets (CLI)
Performing Oracle ILOM User Tasks (CLI)
Restore the Configuration (CLI)
Set the Oracle ILOM CLI Session Timeout (CLI)
Set the Date and Time (CLI)
Set the System Identification Properties (CLI)
Set the Remote Log Hosts (CLI)
Set the Network Management Parameters (CLI)
Set the Date and Time (CLI)
Configure the SNMP Service (CLI)
Set the System Identification Properties (CLI)
Snapshot Dataset Information (CLI)
Install a Custom SSL Certificate (CLI)
Remove the Custom SSL Certificate (CLI)
Display the Switch Chip Port to QSFP Connector Mapping
Disable the Subnet Manager
Disable a Switch Chip Port
Download SNMP Service MIBs (CLI)
Enable a Switch Chip Port
fdconfig Command
Create a Fabric Configuration
Create a Fabric Configuration
Add or Remove an Element From the Fabric Configuration
Create a Fabric Configuration
Display the InfiniBand Fabric Configuration
Modify an Element of the Fabric Configuration
Add or Remove an Element From the Fabric Configuration
Exchange Master Fabric Director Status
Exchange Master Fabric Director Status
Create a Fabric Configuration
Verify Firmware Integrity (CLI)
Determine Changes to the InfiniBand Fabric Topology
Display Switch Chip Port Status
Understanding Hardware Commands
checkboot Command
checkpower Command
checktopomax Command
checkvoltages Command
connector Command
dcsport Command
disablecablelog Command
disablelinklog Command
disablesm Command
disableswitchport Command
enablecablelog Command
enablelinklog Command
enablesm Command
enableswitchport Command
env_test Command
exit Command (Hardware)
fdconfig Command
fwverify Command
generatetopology Command
getfanspeed Command
getmaster Command
getportstatus Command
help Command (Hardware)
listlinkup Command
matchtopology Command
setcontrolledhandover Command
setmsmlocationmonitor Command
setsmmkey Command
setsmpriority Command
setsubnetprefix Command
showfruinfo Command
showpsufru Command
showsmlog Command
showtemps Command
showtopology Command
showunhealthy Command
smconfigtest Command
smnodes Command
smpartition Command
version Command (Hardware)
Identify All HCAs in the Fabric
Identify All Switches in the Fabric
Display a Route Through the Fabric
cd Command
create Command
delete Command
dump Command
exit Command (ILOM)
help Command (ILOM)
load Command
reset Command
set Command
show Command
version Command (ILOM)
Understanding InfiniBand Commands
ibdiagnet Command
ibhosts Command
ibnetdiscover Command
ibnetstatus Command
ibnodes Command
ibportstate Command
ibroute Command
ibrouters Command
ibstat Command
ibswitches Command
ibtracert Command
perfquery Command
saquery Command
smpquery Command
Determine Changes to the InfiniBand Fabric Topology
Display Counters for a Node
Restart the Management Controller
Set the Subnet Manager Prefix
Display Chassis FRU ID
Display Power Supply FRU ID
Display the Subnet Manager Log
Display Internal Temperatures
Display the InfiniBand Fabric Topology (Simple)
Verify the Subnet Manager Configuration Integrity
Use the smnodes Command
smpartition Command
Add or Remove a Port From a Partition
Create a User Partition
Delete a Partition
Display the InfiniBand Fabric Partition Configuration
Modify a Partition or Port
Add or Remove a Port From a Partition
Create a User Partition
SNMP Commands
Access the Management Controller From the Network Management Port
Configuration Overview
Configure the DNS Client (CLI)
Configure the DNS Client (SNMP)
Configure the DNS Client (Web)
Configuring the Fabric Director Node List
Configure the SMTP Client (CLI)
Configure the SMTP Client (SNMP)
Configure the SMTP Client (Web)
Create a Fabric Configuration
Connecting Data cables
Data QSFP Connector and Pins
Network Management Connector and Pins
Data QSFP Connector and Pins
InfiniBand Connector Status Window
USB Management Connector and Pins
connector Command
InfiniBand Connector Status Window
Controlling the Chassis
Controlling the I4 Switch Chip
Controlling Oracle ILOM Targets (CLI)
Controlling Oracle ILOM Targets (SNMP)
Controlling Oracle ILOM Targets (Web)
Controlling the InfiniBand Fabric
Controlling the Subnet Manager
Create a Fabric Configuration
Create a User Partition