man pages section 1M: System Administration Commands

Exit Print View

Updated: July 2014
 
 

ibsysstat (1m)

Name

ibsysstat - system status on an InfiniBand address

Synopsis

ibsysstat  [-d(ebug)]  [-e(rr_show)]  [-v(erbose)] [-G(uid)]
[-C ca_name] [-P ca_port] [-s smlid] [-t(imeout) timeout_ms]
[-V(ersion)]  [-o  oui]  [-S(erver)]  [-h(elp)]  <dest lid |
guid> [<op>]

Description




OpenIB Diagnostics                                  IBSYSSTAT(1m)



NAME
     ibsysstat - system status on an InfiniBand address


SYNOPSIS
     ibsysstat  [-d(ebug)]  [-e(rr_show)]  [-v(erbose)] [-G(uid)]
     [-C ca_name] [-P ca_port] [-s smlid] [-t(imeout) timeout_ms]
     [-V(ersion)]  [-o  oui]  [-S(erver)]  [-h(elp)]  <dest lid |
     guid> [<op>]


DESCRIPTION
     ibsysstat uses vendor mads to validate connectivity  between
     IB  nodes  and  obtain  other information about the IB node.
     ibsysstat is run as client/server.  Default  is  to  run  as
     client.


OPTIONS
     Current supported operations:
           ping - verify connectivity to server (default)
           host - obtain host information from server
           cpu  - obtain cpu information from server

     -o, --oui
          use specified OUI number to multiplex vendor mads

     -S, --Server
          start in server mode (do not return)



COMMON OPTIONS
     Most OpenIB diagnostics take the following common flags. The
     exact list of supported flags per utility can  be  found  in
     the  usage  message  and can be shown using the util_name -h
     syntax.

     # Debugging flags

     -d      raise the IB debugging level.
             May be used several times (-ddd or -d -d -d).

     -e      show send and receive errors (timeouts and others)

     -h      show the usage message

     -v      increase the application verbosity level.
             May be used several times (-vv or -v -v -v)

     -V      show the version info.




OpenIB             Last change: August 11, 2006                 1






OpenIB Diagnostics                                  IBSYSSTAT(1m)



     # Addressing flags

     -G      use GUID address argument. In most cases, it is  the
     Port GUID.
             Example:
             "0x08f1040023"

     -s  <smlid>       use  'smlid'  as  the target lid for SM/SA
     queries.

     # Other common flags:

     -C <ca_name>    use the specified ca_name.

     -P <ca_port>    use the specified ca_port.

     -t  <timeout_ms>  override  the  default  timeout  for   the
     solicited mads.

     Multiple CA/Multiple Port Support

     When  no  IB device or port is specified, the port to use is
     selected by the following criteria:

     1. the first port that is ACTIVE.

     2. if not found, the first port that is  UP  (physical  link
     up).

     If  a  port and/or CA name is specified, the user request is
     attempted to be fulfilled, and will fail if it is not possi-
     ble.


AUTHOR
     Hal Rosenstock
          <halr@voltaire.com>



ATTRIBUTES
     See   attributes(5)   for   descriptions  of  the  following
     attributes:

     +---------------+----------------------+
     |ATTRIBUTE TYPE |   ATTRIBUTE VALUE    |
     +---------------+----------------------+
     |Availability   | network/open-fabrics |
     +---------------+----------------------+
     |Stability      | Volatile             |
     +---------------+----------------------+




OpenIB             Last change: August 11, 2006                 2






OpenIB Diagnostics                                  IBSYSSTAT(1m)



NOTES
     This  software  was   built   from   source   available   at
     https://java.net/projects/solaris-userland.    The  original
     community source was downloaded from   ['http://www.openfab-
     rics.org/downloads/ibutils/ibutils-1.5.7.tar.gz',
     'http://www.openfabrics.org/downloads/libibverbs/libib-
     verbs-1.1.4-1.22.g7257cd3.tar.gz',      'http://www.openfab-
     rics.org/down-
     loads/libmlx4/libmlx4-1.0.1-1.18.gb810a27.tar.gz',
     'http://www.openfabrics.org/downloads/libsdp/lib-
     sdp-1.1.108-0.15.gd7fdb72.tar.gz',      'http://www.openfab-
     rics.org/downloads/management/infiniband-
     diags-1.5.8.tar.gz',       'http://www.openfabrics.org/down-
     loads/management/libibmad-1.3.7.tar.gz',   'http://www.open-
     fabrics.org/downloads/management/libibumad-1.3.7.tar.gz',
     'http://www.openfabrics.org/downloads/manage-
     ment/opensm-3.3.9.tar.gz', 'http://www.openfabrics.org/down-
     loads/perftest/perftest-1.3.0-0.42.gf350d3d.tar.gz',
     'http://www.openfabrics.org/down-
     loads/qperf/qperf-0.4.6-0.1.gb81434e.tar.gz',
     'http://www.openfabrics.org/downloads/rdmacm/librd-
     macm-1.0.14.1.tar.gz',     'http://www.openfabrics.org/down-
     loads/rds-tools/rds-tools-2.0.4.tar.gz']

     Further  information about this software can be found on the
     open  source  community   website   at   http://www.openfab-
     rics.org/.




























OpenIB             Last change: August 11, 2006                 3