SPARC T7-2 Server Service Manual

Exit Print View

Updated: July 2019
 
 

Attaching Devices During Service

During service procedures, you might have to connect devices to the server.

  • For OS support, connect an Ethernet cable to the one of the Ethernet connectors (NET 0, NET 1, NET 2, and NET 3).

  • If you plan to interact with the system console directly, you can connect additional external devices, such as a mouse and keyboard, to the server's USB connectors, and connect a monitor to a DB-15 video connector. The front DB-15 video connector is active by default. To enable the rear port and disable the front port, you must enable the Oracle ILOM VGA_REAR_PORT policy: -> set /SP/policy VGA_REAR_PORT=enabled. For more details on selecting an active video port, refer to Accessing the Server in SPARC T7 Series Servers Administration Guide.

  • If you plan to connect to the Oracle ILOM software over the network, connect an Ethernet cable to the Ethernet port labeled NET MGT.


    Note -  The SPM uses the NET MGT (out-of-band) port by default. You can configure the SPM to share one of the sever's four Ethernet ports instead. The SPM uses only the configured Ethernet port.
  • If you plan to access the Oracle ILOM CLI through the SER MGT port, connect a serial null modem cable to the RJ-45 serial port labeled SER MGT.

  • The USB connectors on the front panel support USB 2.0. The USB connectors on the rear panel support USB 3.0.