1
|
System Server Locator LED and button (white)
|
|
You can turn on the Locator LED to identify a particular
server. When lit, the LED blinks rapidly. Turn on the Locator
LED by pressing the Locator button with a stylus, or see Locate the Server.
|
2
|
Service Action Required LED (amber)
|
|
Under some fault conditions, individual component fault LEDs
are lit in addition to the Service Action Required LED.
|
3
|
Power OK LED (green)
|
|
Indicates these conditions:
-
Off – Server
is not running in its normal state. Server power might
be off. The SPM might be running.
-
Steady on –
Server is powered on and is running in its normal
operating state. No service actions are required.
-
Fast blink –
Server is running in standby mode and can be quickly
returned to full function.
-
Slow blink –
A normal but transitory activity is taking place. Slow
blinking might indicate that server diagnostics are
running or that the server is booting.
|
4
|
SP OK LED
|
SP
|
Indicates these conditions:
-
Off – AC
power might have been connected to the power
supplies.
-
Steady on, green
– SPM is running in its normal operating state. No
service actions are required.
-
Blink, green
– SPM is initializing the Oracle ILOM
firmware.
-
Steady on, amber
– An SPM error has occurred and service is
required.
|
5
|
Fan Module Fault LED (amber)
|
FAN
|
Indicates these conditions:
-
Off – Steady
state, no service action is required.
-
Steady on – A
fan module failure event has been acknowledged and a
service action is required on at least one of the fan
modules.
|
6
|
CPU Fault LED (amber)
|
CPU
|
Indicates these conditions:
-
Off – Steady
state, no service action is required.
-
Steady on – A
fault has been detected on one or more host
processors.
|
7
|
Memory DIMM Fault LED (amber)
|
MEM
|
Indicates these conditions:
-
Off – Steady
state, no service action is required.
-
Steady on – A
fault has been detected on one or more DIMMs.
|
8
|
Server Power Supply Fault LED (amber)
|
PS
|
Indicates these conditions:
-
Off – Steady
state, no service action is required.
-
Steady on – A
fault has been detected on one of the two power
supplies.
|
9
|
Server Overtemp LED (amber)
|
|
Indicates these conditions:
-
Off – Steady
state, no service action is required.
-
Steady on – A
temperature failure event has been acknowledged. A
temperature limit has been exceeded and a service action
is required.
|