Go to main content

SPARC T7-2 Server Service Manual

Exit Print View

Updated: July 2019
 
 

Identify Faulted Components

The fmadm faulty command displays the list of faults detected by PSH. You can run this command from the host or through the Oracle ILOM fault management shell.

  1. From the Oracle ILOM prompt, start the fault management shell and type fmadm faulty.

    This example shows how to check for faults through the Oracle ILOM fault management shell. You can also check for faults by typing show faulty at the Oracle ILOM prompt.

    -> start /SP/faultmgmt/shell
    Are you sure you want to start /SP/faultmgmt/shell (y/n)? y
     
    faultmgmtsp> fmadm faulty
    ------------------- ------------------------------------ -------------- -------
    Time                UUID                                 msgid          Severity
    ------------------- ------------------------------------ -------------- -------
    2015-01-16/17:55:26 f4ee56c-9fdd-ca19-efb5-ae39675dfee3  SPT-8000-PX    Major
     
    Problem Status   : open
    Diag Engine      : fdd 1.0
    System
      Manufacturer   : Oracle Corporation
      Name           : SPARC T7-2
      Part_Number    : 12345678+11+1
      Serial_Number  : 1238BDC0DF
     
    ----------------------------------------
    Suspect 1 of 1
      Fault class  : fault.component.misconfigured
      Certainty    : 100%
      Affects      : /SYS/MB/CM1/CMP/MR3/BOB1/CH1/DIMM
      Status       : faulted
      FRU
         Status      : faulty
         Location    : /SYS/MB/CM1/CMP/MR3/BOB1/CH1/DIMM
         Manufacturer      : Hynix Semiconductor Inc.
         Name              : 8192MB DDR4 SDRAM DIMM
         Part_Number       : 70xx001,HMA4xxR7MFRxx-TFT7
         Revision          : 01
         Serial_Number     : 465769T+02xxx102WR
         Chassis
            Manufacturer   : Oracle Corporation
            Name           : SPARC T7-2
            Part_Number    : 12345678+13+2
            Serial_Number  : 1248DC140
     
    Description : A FRU has been inserted into a location where it is not
                  supported.
     
    Response    : The service required LED on the chassis may be illuminated.
     
    Impact      : The FRU may not be usable in its current location.
     
    Action      : Please refer to the associated reference document at
                  http://support.oracle.com/msg/SPT-8000-PX for the latest
                  service procedures and policies regarding this diagnosis.
    faultmgmtsp>
     
     
    

    In this example, a fault is displayed that includes these details:

    • Date and time of the fault (2015-01-16/17:55:26).

    • UUID (f4ee56c-9fdd-ca19-efb5-ae39675dfee3), which is unique to each fault.

    • Message ID (SPT-8000-PX), which can be used to obtain additional fault information from Knowledge Base articles.

  2. Use the message ID to obtain more information about this type of fault.
    1. Obtain the message ID from console output (SPT-8000-PX in the example above).
    2. Go to https://support.oracle.com, and search on the message ID in the Knowledge tab, or type the URL from the Action field into a browser.
  3. Follow the suggested actions to repair the fault.
  4. If necessary, clear the fault manually.

    See Clear a Fault Manually.

Related Information