Powering the Host On and Off

Your server has three power modes (states): power off, Standby power, and Main power.

Power State
Description
Indicators
Action
Power off
The server is completely powered off when the AC power cords are disconnected.
All indicators are off.
The server is disconnected from all power sources.
Disconnect all four power cords to completely remove power.

Caution  -  Equipment damage. Do not disconnect power cords when system is in Main power mode. Place all systems in Standby power mode before disconnecting power cords.

Standby power
In Standby power mode, the host is powered off but the SP is powered on.
The green system System OK indicator flashes slowly.
The green SP OK indicator is steady on.
If the server is completely powered off, plug in all four power cords to apply Standby power.
If the server is in Main power mode, use Oracle ILOM or the Power button to remove host power. On dual 4-socket systems, complete this action for both servers.
You can power the host off gracefully, or immediately.
Main power
When you power on the host, the server enters Main power mode.
In Main power mode, the green System OK indicator is steady on.
On single 4-socket and single 8-socket systems,only the System OK indicator for System A (SMOD0) comes on.
Use Oracle ILOM or the On/Standby button to apply host power.
On dual 4-socket systems, you must complete this action for both servers.

For instructions on powering the host off and on, see the following procedures: