Understanding the Switched NEM
Switched NEM Features Overview
Installing or Replacing the Switched NEM
Verifying the Switched NEM Installation
Verify Installation With the CMM ILOM Web Interface
Verify Installation With the CMM ILOM CLI
Finish the Switched NEM Installation
Install the Fabric Expansion Module in the Server Blade
Installing or Removing SFP+ or QSFP Optical Transceiver Modules
Install an SFP+ or QSFP Optical Transceiver Module
Remove an SFP+ or QFSP Optical Transceiver Module
Managing the NEM Remotely (ILOM)
Configuring an Externally Accessible IP Address on the NEM
Connecting to the NEM ILOM Through the CMM ILOM
Configure SEFOS User Privileges
Special Considerations for RADIUS Users
Configure User Privileges for RADIUS Users
Backing Up and Restoring the ILOM and SEFOS Configuration
You can connect to the ILOM CLI using any of the following methods:
Enter the following commands to connect to the NEM SEFOS:
-> cd /NEM/fs_cli/
If the ILOM user with privilege level 15, user has full administrative rights. The SEFOS# prompt will appear. For example:
-> cd /NEM/fs_cli/ cd: Connecting to Fabric Switch CLI SEFOS#
If the ILOM user with privilege level 1, user has read only rights. The SEFOS> prompt will appear. For example:
-> cd /NEM/fs_cli/ cd: Connecting to Fabric Switch CLI SEFOS>
Enter the following command to connect to the CLI:
-> start /NEM/fs_cli/ Are you sure you want to start /NEM/fs_cli (y/n?) y start: Connecting to Fabric Switch CLI SEFOS#
You can now configure SEFOS. Refer to the Sun Blade 6000 Ethernet Switched NEM 24p 10GbE Software Configuration Guide for instructions.
For example:
SEFOS# exit Connection closed by foreign host. cd: The session with /NEM/fs_cli has ended. ->
-> exit