10 GbE Client Access Connections

Two of the four dual-ported Sun Dual 10 GbE SFP+ PCIe 2.0 Low Profile NICs in the SPARC T4-4 server are assigned to the Application Domain running Oracle Solaris 10, installed in these slots in the SPARC T4-4 server:

  • Express module slot 6

  • Express module slot 14

One port from each dual-ported 10 GbE NIC will be part of one IPMP group to provide redundancy. The IPMP grouping will be set during the initial configuration when the SPARC SuperCluster T4-4 is first installed at the customer site. In this example, the following ports are part of one IPMP group and are used for the physical connection to the 10 GbE network for the Application Domain running Oracle Solaris 10:

  • 10 GbE NIC in express module slot 6 – Port 0

  • 10 GbE NIC in express module slot 14 – Port 1