InfiniBand Fabric
The following tables show InfiniBand (IB) connections for these switches.
IB Spine Switch
Table 14 IB Spine Switch (U1) Connections
|
|
|
|
|
U1
|
1B
|
Leaf switch 1
|
U18
|
8B
|
U1
|
0B
|
Leaf switch 2
|
U24
|
8B
|
|
IB Leaf Switch No. 1
Table 15 Full Rack Connections for IB Leaf Switch 1
(U18)
|
|
|
|
|
U18
|
0A
|
T4-4 No. 4
|
U32
|
PCIE-12 P2
|
U18
|
0B
|
T4-4 No. 4
|
U32
|
PCIE-9 P2
|
U18
|
1A
|
T4-4 No. 4
|
U32
|
PCIE-7 P2
|
U18
|
1B
|
T4-4 No. 4
|
U32
|
PCIE-1 P2
|
U18
|
2A
|
—
|
—
|
—
|
U18
|
2B
|
—
|
—
|
—
|
U18
|
3A
|
Sun ZFS Storage 7320 storage controllers No. 2
|
U26
|
PCIE-0 P1
|
U18
|
3B
|
T4-4 No. 2
|
U13
|
PCIE-12 P1
|
U18
|
4A
|
T4-4 No. 2
|
U13
|
PCIE-9 P1
|
U18
|
4B
|
T4-4 No. 2
|
U13
|
PCIE-7 P1
|
U18
|
5A
|
T4-4 No. 2
|
U13
|
PCIE-1 P1
|
U18
|
5B
|
T4-4 No. 3
|
U27
|
PCIE-12 P2
|
U18
|
6A
|
T4-4 No. 3
|
U27
|
PCIE-9 P2
|
U18
|
6B
|
T4-4 No. 3
|
U27
|
PCIE-7 P2
|
U18
|
7A
|
T4-4 No. 3
|
U27
|
PCIE-1 P2
|
U18
|
7B
|
—
|
—
|
—
|
U18
|
8A
|
IB leaf switch 2
|
U24
|
8A
|
U18
|
8B
|
IB spine switch
|
U1
|
1B
|
U18
|
9A
|
IB leaf switch 2
|
U24
|
9B
|
U18
|
9B
|
IB leaf switch 2
|
U24
|
9A
|
U18
|
10A
|
IB leaf switch 2
|
U24
|
10B
|
U18
|
10B
|
IB leaf switch 2
|
U24
|
10A
|
U18
|
11A
|
IB leaf switch 2
|
U24
|
11B
|
U18
|
11B
|
IB leaf switch 2
|
U24
|
11A
|
U18
|
12A
|
—
|
—
|
—
|
U18
|
12B
|
T4-4 No. 1
|
U8
|
PCIE-12 P1
|
U18
|
13A
|
T4-4 No. 1
|
U8
|
PCIE-9 P1
|
U18
|
13B
|
T4-4 No. 1
|
U8
|
PCIE-7 P1
|
U18
|
14A
|
T4-4 No. 1
|
U8
|
PCIE-1 P1
|
U18
|
14B
|
Sun ZFS Storage 7320 storage controller No. 1
|
U25
|
PCIE-0 P1
|
U18
|
15A
|
Exadata Storage Server No. 6
|
U41
|
PCIE-3 P2
|
U18
|
15B
|
Exadata Storage Server No. 5
|
U39
|
PCIE-3 P2
|
U18
|
16A
|
Exadata Storage Server No. 4
|
U37
|
PCIE-3 P2
|
U18
|
16B
|
Exadata Storage Server No. 3
|
U6
|
PCIE-3 P1
|
U18
|
17A
|
Exadata Storage Server No. 2
|
U4
|
PCIE-3 P1
|
U18
|
17B
|
Exadata Storage Server No. 1
|
U2
|
PCIE-3 P1
|
|
Table 16 Half Rack Connections for IB Leaf Switch
No. 1 (U18)
|
|
|
|
|
U18
|
0A
|
—
|
—
|
—
|
U18
|
0B
|
—
|
—
|
—
|
U18
|
1A
|
—
|
—
|
—
|
U18
|
1B
|
—
|
—
|
—
|
U18
|
2A
|
—
|
—
|
—
|
U18
|
2B
|
—
|
—
|
—
|
U18
|
3A
|
Sun ZFS Storage 7320 storage controllers No. 2
|
U26
|
PCIE-0 P1
|
U18
|
3B
|
T4-4 No. 2
|
U13
|
PCIE-12 P1
|
U18
|
4A
|
T4-4 No. 2
|
U13
|
PCIE-9 P1
|
U18
|
4B
|
T4-4 No. 2
|
U13
|
PCIE-7 P1
|
U18
|
5A
|
T4-4 No. 2
|
U13
|
PCIE-1 P1
|
U18
|
5B
|
—
|
—
|
—
|
U18
|
6A
|
—
|
—
|
—
|
U18
|
6B
|
—
|
—
|
—
|
U18
|
7A
|
—
|
—
|
—
|
U18
|
7B
|
—
|
—
|
—
|
U18
|
8A
|
IB leaf switch No. 2
|
U24
|
8A
|
U18
|
8B
|
IB spine switch
|
U1
|
1B
|
U18
|
9A
|
IB leaf switch No. 2
|
U24
|
9B
|
U18
|
9B
|
IB leaf switch No. 2
|
U24
|
9A
|
U18
|
10A
|
IB leaf switch No. 2
|
U24
|
10B
|
U18
|
10B
|
IB leaf switch No. 2
|
U24
|
10A
|
U18
|
11A
|
IB leaf switch No. 2
|
U24
|
11B
|
U18
|
11B
|
IB leaf switch No. 2
|
U24
|
11A
|
U18
|
12A
|
—
|
—
|
—
|
U18
|
12B
|
T4-4 No. 1
|
U8
|
PCIE-12 P1
|
U18
|
13A
|
T4-4 No. 1
|
U8
|
PCIE-9 P1
|
U18
|
13B
|
T4-4 No. 1
|
U8
|
PCIE-7 P1
|
U18
|
14A
|
T4-4 No. 1
|
U8
|
PCIE-1 P1
|
U18
|
14B
|
Sun ZFS Storage 7320 storage controller No. 1
|
U25
|
PCIE-0 P1
|
U18
|
15A
|
—
|
—
|
—
|
U18
|
15B
|
—
|
—
|
—
|
U18
|
16A
|
—
|
—
|
—
|
U18
|
16B
|
Exadata Storage Server No. 3
|
U6
|
PCIE-3 P1
|
U18
|
17A
|
Exadata Storage Server No. 2
|
U4
|
PCIE-3 P1
|
U18
|
17B
|
Exadata Storage Server No. 1
|
U2
|
PCIE-3 P1
|
|
IB Leaf Switch No. 2
Table 17 Full Rack Connections for IB Leaf Switch
No. 2 (U24)
|
|
|
|
|
U24
|
0A
|
T4-4 No. 4
|
U32
|
PCIE-12 P1
|
U24
|
0B
|
T4-4 No. 4
|
U32
|
PCIE-9 P1
|
U24
|
1A
|
T4-4 No. 4
|
U32
|
PCIE-7 P1
|
U24
|
1B
|
T4-4 No. 4
|
U32
|
PCIE-1 P1
|
U24
|
2A
|
—
|
—
|
—
|
U24
|
2B
|
—
|
—
|
—
|
U24
|
3A
|
Sun ZFS Storage 7320 storage controller No. 2
|
U26
|
PCIE-0 P2
|
U24
|
3B
|
T4-4 No. 2
|
U13
|
PCIE-12 P2
|
U24
|
4A
|
T4-4 No. 2
|
U13
|
PCIE-9 P2
|
U24
|
4B
|
T4-4 No. 2
|
U13
|
PCIE-7 P2
|
U24
|
5A
|
T4-4 No. 2
|
U13
|
PCIE-1 P2
|
U24
|
5B
|
T4-4 No. 3
|
U27
|
PCIE-12 P1
|
U24
|
6A
|
T4-4 No. 3
|
U27
|
PCIE-9 P1
|
U24
|
6B
|
T4-4 No. 3
|
U27
|
PCIE-7 P1
|
U24
|
7A
|
T4-4 No. 3
|
U27
|
PCIE-1 P1
|
U24
|
7B
|
—
|
—
|
—
|
U24
|
8A
|
IB leaf switch No. 1
|
U18
|
8A
|
U24
|
8B
|
IB spine switch
|
U1
|
0B
|
U24
|
9A
|
IB leaf switch No. 1
|
U18
|
9B
|
U24
|
9B
|
IB leaf switch No. 1
|
U18
|
9A
|
U24
|
10A
|
IB leaf switch No. 1
|
U18
|
10B
|
U24
|
10B
|
IB leaf switch No. 1
|
U18
|
10A
|
U24
|
11A
|
IB leaf switch No. 1
|
U18
|
11B
|
U24
|
11B
|
IB leaf switch No. 1
|
U18
|
11A
|
U24
|
12A
|
—
|
—
|
—
|
U24
|
12B
|
T4-4 No. 1
|
U8
|
PCIE-12 P2
|
U24
|
13A
|
T4-4 No. 1
|
U8
|
PCIE-9 P2
|
U24
|
13B
|
T4-4 No. 1
|
U8
|
PCIE-7 P2
|
U24
|
14A
|
T4-4 No. 1
|
U8
|
PCIE-1 P2
|
U24
|
14B
|
Sun ZFS Storage 7320 storage controller No. 1
|
U25
|
PCIE-0 P2
|
U24
|
15A
|
Exadata Storage Server No. 6
|
U41
|
PCIE 3 P1
|
U24
|
15B
|
Exadata Storage Server No. 5
|
U39
|
PCIE 3 P1
|
U24
|
16A
|
Exadata Storage Server No. 4
|
U37
|
PCIE 3 P1
|
U24
|
16B
|
Exadata Storage Server No. 3
|
U6
|
PCIE-3 P2
|
U24
|
17A
|
Exadata Storage Server No. 2
|
U4
|
PCIE-3 P2
|
U24
|
17B
|
Exadata Storage Server No. 1
|
U2
|
PCIE-3 P2
|
|
Table 18 Half Rack Connections for IB Leaf Switch
No. 2 (U24)
|
|
|
|
|
U24
|
0A
|
—
|
—
|
—
|
U24
|
0B
|
—
|
—
|
—
|
U24
|
1A
|
—
|
—
|
—
|
U24
|
1B
|
—
|
—
|
—
|
U24
|
2A
|
—
|
—
|
—
|
U24
|
2B
|
—
|
—
|
—
|
U24
|
3A
|
Sun ZFS Storage 7320 storage controller No. 2
|
U26
|
PCIE-0 P2
|
U24
|
3B
|
T4-4 No. 2
|
U13
|
PCIE-12 P2
|
U24
|
4A
|
T4-4 No. 2
|
U13
|
PCIE-9 P2
|
U24
|
4B
|
T4-4 No. 2
|
U13
|
PCIE-7 P2
|
U24
|
5A
|
T4-4 No. 2
|
U13
|
PCIE-1 P2
|
U24
|
5B
|
—
|
—
|
—
|
U24
|
6A
|
—
|
—
|
—
|
U24
|
6B
|
—
|
—
|
—
|
U24
|
7A
|
—
|
—
|
—
|
U24
|
7B
|
—
|
—
|
—
|
U24
|
8A
|
IB leaf switch No. 1
|
U18
|
8A
|
U24
|
8B
|
IB spine switch
|
U1
|
0B
|
U24
|
9A
|
IB leaf switch No. 1
|
U18
|
9B
|
U24
|
9B
|
IB leaf switch No. 1
|
U18
|
9A
|
U24
|
10A
|
IB leaf switch No. 1
|
U18
|
10B
|
U24
|
10B
|
IB leaf switch No. 1
|
U18
|
10A
|
U24
|
11A
|
IB leaf switch No. 1
|
U18
|
11B
|
U24
|
11B
|
IB leaf switch No. 1
|
U18
|
11A
|
U24
|
12A
|
—
|
—
|
—
|
U24
|
12B
|
T4-4 No. 1
|
U8
|
PCIE-12 P2
|
U24
|
13A
|
T4-4 No. 1
|
U8
|
PCIE-9 P2
|
U24
|
13B
|
T4-4 No. 1
|
U8
|
PCIE-7 P2
|
U24
|
14A
|
T4-4 No. 1
|
U8
|
PCIE-1 P2
|
U24
|
14B
|
Sun ZFS Storage 7320 storage controller No. 1
|
U25
|
PCIE-0 P2
|
U24
|
15A
|
—
|
—
|
—
|
U24
|
15B
|
—
|
—
|
—
|
U24
|
16A
|
—
|
—
|
—
|
U24
|
16B
|
Exadata Storage Server No. 3
|
U6
|
PCIE-3 P2
|
U24
|
17A
|
Exadata Storage Server No. 2
|
U4
|
PCIE-3 P2
|
U24
|
17B
|
Exadata Storage Server No. 1
|
U2
|
PCIE-3 P2
|
|