Ethernet Management Switch
The Ethernet management switch (Cisco Catalyst 4948 10 Gigabit Ethernet Switch, Figure 16) is
located in the SPARC SuperCluster T4-4 at location U19.
The Ethernet management switch connects to the SPARC T4-4 servers, Sun ZFS Storage
7320 storage controllers, Exadata Storage Servers, and PDUs through the ports listed in
the following tables.
Table 19 lists cables for the Ethernet Management switch in a full rack.
Table 20 lists cables for the Ethernet Management switch in a half rack.
Note -
Ethernet management switch port numbers 45, 46, 47, and 48 are shared between item
4 (10BASE-T/100BASE-TX/1000BASE-T Ethernet) and item 6 (1000BASE-X Ethernet)
Note -
Ethernet management switch ports 1, 2, 3, and 4 are not used at this time.
Ethernet Management Switch Connections in a Full Rack
Table 19 Full Rack Cat 5E Cables for Ethernet
Management Switch (U19)
|
|
|
|
|
1
|
—
|
—
|
—
|
—
|
2
|
—
|
—
|
—
|
—
|
3
|
—
|
—
|
—
|
—
|
4
|
—
|
—
|
—
|
—
|
5
|
T4-4 No. 4
|
U32
|
NET 3
|
Black, 3 m
|
6
|
T4-4 No. 3
|
U27
|
NET 3
|
Black, 3 m
|
7
|
T4-4 No. 4
|
U32
|
NET 2
|
Black, 3 m
|
8
|
T4-4 No. 3
|
U27
|
NET 2
|
Black, 3 m
|
9
|
T4-4 No. 4
|
U32
|
NET 1
|
Black, 3 m
|
10
|
T4-4 No. 3
|
U27
|
NET 1
|
Black, 3 m
|
11
|
T4-4 No. 4
|
U32
|
NET 0
|
Black, 3 m
|
12
|
T4-4 No. 4
|
U32
|
NET MGT
|
Red, 3 m
|
13
|
T4-4 No. 3
|
U27
|
NET-0
|
Black, 3 m
|
14
|
T4-4 No. 3
|
U27
|
NET MGT
|
Red, 3 m
|
15
|
PDU-A
|
PDU-A
|
NET MGT
|
White, 1 m
|
16
|
T4-4 No. 2
|
U13
|
NET-1
|
Black, 3 m
|
17
|
T4-4 No. 2
|
U13
|
NET-0
|
Black, 3 m
|
18
|
T4-4 No. 2
|
U13
|
NET MGT
|
Red, 3 m
|
19
|
PDU-B
|
PDU-B
|
NET MGT
|
White, 1 m
|
20
|
T4-4 No. 2
|
U13
|
NET-2
|
Black, 3 m
|
21
|
T4-4 No. 1
|
U8
|
NET-0
|
Black, 3 m
|
22
|
T4-4 No. 1
|
U8
|
NET MGT
|
Red, 3 m
|
23
|
Sun ZFS Storage 7320 storage controller No. 2
|
U26
|
NET-1
|
Blue, 3 m
|
24
|
T4-4 No. 2
|
U13
|
NET-3
|
Black, 3 m
|
25
|
Sun ZFS Storage 7320 storage controller No. 2
|
U26
|
NET-0
|
Blue, 3 m
|
26
|
T4-4 No. 1
|
U8
|
NET-1
|
Black, 3 m
|
27
|
Sun ZFS Storage 7320 storage controller No. 2
|
U26
|
NET-2
|
Blue, 3 m
|
28
|
T4-4 No. 1
|
U8
|
NET-2
|
Black, 3 m
|
29
|
Sun ZFS Storage 7320 storage controller No. 1
|
U25
|
NET-1
|
Blue, 3 m
|
30
|
T4-4 No. 1
|
U8
|
NET-3
|
Black, 3 m
|
31
|
Sun ZFS Storage 7320 storage controller No. 1
|
U25
|
NET-0
|
Blue, 3 m
|
32
|
Sun ZFS Storage 7320 storage controller No. 1
|
U25
|
NET-2
|
Blue, 3 m
|
33
|
Exadata Storage Server No. 6
|
U41
|
NET-0
|
Black, 3 m
|
34
|
Exadata Storage Server No. 6
|
U41
|
NET MGT
|
Red, 3 m
|
35
|
Exadata Storage Server No. 5
|
U39
|
NET-0
|
Black, 3 m
|
36
|
Exadata Storage Server No. 5
|
U39
|
NET MGT
|
Red, 3 m
|
37
|
Exadata Storage Server No. 4
|
U37
|
NET-0
|
Black, 3 m
|
38
|
Exadata Storage Server No. 4
|
U37
|
NET MGT
|
Red, 3 m
|
39
|
Exadata Storage Server No. 3
|
U6
|
NET-0
|
Black, 3 m
|
40
|
Exadata Storage Server No. 3
|
U6
|
NET MGT
|
Red, 3 m
|
41
|
Exadata Storage Server No. 2
|
U4
|
NET-0
|
Black, 3 m
|
42
|
Exadata Storage Server No. 2
|
U4
|
NET MGT
|
Red, 3 m
|
43
|
Exadata Storage Server No. 1
|
U2
|
NET-0
|
Black, 3 m
|
44
|
Exadata Storage Server No. 1
|
U2
|
NET MGT
|
Red, 3 m
|
45
|
Sun Datacenter InfiniBand Switch 36 Leaf No. 2
|
U24
|
NET-0
|
Black, 3 m
|
46
|
Sun Datacenter InfiniBand Switch 36 Leaf No. 1
|
U18
|
NET-0
|
Black, 3 m
|
47
|
Sun Datacenter InfiniBand Switch 36 Spine
|
U1
|
NET-0
|
Black, 3 m
|
48
|
(Reserved for service access)
|
—
|
—
|
Blue, 3 m
|
|
Ethernet Management Switch Connections in a Half Rack
Table 20 Half Rack Cat 5E Cables for Ethernet
Management Switch (U19)
|
|
|
|
|
1
|
—
|
—
|
—
|
—
|
2
|
—
|
—
|
—
|
—
|
3
|
—
|
—
|
—
|
—
|
4
|
—
|
—
|
—
|
—
|
5
|
—
|
—
|
—
|
—
|
6
|
—
|
—
|
—
|
—
|
7
|
—
|
—
|
—
|
—
|
8
|
—
|
—
|
—
|
—
|
9
|
—
|
—
|
—
|
—
|
10
|
—
|
—
|
—
|
—
|
11
|
—
|
—
|
—
|
—
|
12
|
—
|
—
|
—
|
—
|
13
|
—
|
—
|
—
|
—
|
14
|
—
|
—
|
—
|
—
|
15
|
PDU-A
|
PDU-A
|
NET MGT
|
White, 1 m
|
16
|
T4-4 No. 2
|
U13
|
NET-1
|
Black, 3 m
|
17
|
T4-4 No. 2
|
U13
|
NET-0
|
Black, 3 m
|
18
|
T4-4 No. 2
|
U13
|
NET MGT
|
Red, 3 m
|
19
|
PDU-B
|
PDU-B
|
NET MGT
|
White, 1 m
|
20
|
T4-4 No. 2
|
U13
|
NET-2
|
Black, 3 m
|
21
|
T4-4 No. 1
|
U8
|
NET-0
|
Black, 3 m
|
22
|
T4-4 No. 1
|
U8
|
NET MGT
|
Red, 3 m
|
23
|
Sun ZFS Storage 7320 storage controller No. 2
|
U26
|
NET-1
|
Blue, 3 m
|
24
|
T4-4 No. 2
|
U13
|
NET-3
|
Black, 3 m
|
25
|
Sun ZFS Storage 7320 storage controller No. 2
|
U26
|
NET-0
|
Blue, 3 m
|
26
|
T4-4 No. 1
|
U8
|
NET-1
|
Black, 3 m
|
27
|
Sun ZFS Storage 7320 storage controller No. 2
|
U26
|
NET-2
|
Blue, 3 m
|
28
|
T4-4 No. 1
|
U8
|
NET-2
|
Black, 3 m
|
29
|
Sun ZFS Storage 7320 storage controller No. 1
|
U25
|
NET-1
|
Blue, 3 m
|
30
|
T4-4 No. 1
|
U8
|
NET-3
|
Black, 3 m
|
31
|
Sun ZFS Storage 7320 storage controller No. 1
|
U25
|
NET-0
|
Blue, 3 m
|
32
|
Sun ZFS Storage 7320 storage controller No. 1
|
U25
|
NET-2
|
Blue, 3 m
|
33
|
—
|
—
|
—
|
—
|
34
|
—
|
—
|
—
|
—
|
35
|
—
|
—
|
—
|
—
|
36
|
—
|
—
|
—
|
—
|
37
|
—
|
—
|
—
|
—
|
38
|
—
|
—
|
—
|
—
|
39
|
Exadata Storage Server No. 3
|
U6
|
NET-0
|
Black, 3 m
|
40
|
Exadata Storage Server No. 3
|
U6
|
NET MGT
|
Red, 3 m
|
41
|
Exadata Storage Server No. 2
|
U4
|
NET-0
|
Black, 3 m
|
42
|
Exadata Storage Server No. 2
|
U4
|
NET MGT
|
Red, 3 m
|
43
|
Exadata Storage Server No. 1
|
U2
|
NET-0
|
Black, 3 m
|
44
|
Exadata Storage Server No. 1
|
U2
|
NET MGT
|
Red, 3 m
|
45
|
Sun Datacenter InfiniBand Switch 36 Leaf No. 2
|
U24
|
NET-0
|
Black, 3 m
|
46
|
Sun Datacenter InfiniBand Switch 36 Leaf No. 1
|
U18
|
NET-0
|
Black, 3 m
|
47
|
Sun Datacenter InfiniBand Switch 36 Spine
|
U1
|
NET-0
|
Black, 3 m
|
48
|
(Reserved for service access)
|
—
|
—
|
Blue, 3 m
|
|