Power Supply Status Indicators

Each power supply contains two status indicators (LEDs) on the back panel. The following figure and table provide a description of the power supply status indicators.

image:Figure showing the location of the power supply                         status LEDs. Table 11  Server Power Supply Indicators
Legend
Status Indicator Name
Icon
Color
State Meaning
1
AC OK/DC OK
image:OK LED icon
Green
  • OFF – No AC power is present.

  • SLOW BLINK – Normal operating. Input power is within specification. DC output voltage is not enabled.

  • STEADY ON – Normal operation. Input AC power and DC output voltage are within specification.

2
Service Required
image:Service required LED                                         icon
Amber
  • OFF – Normal operation; no service required.

  • STEADY ON – The power supply (PS) has detected a PS fan failure, PS overtemperature, PS over current, or PS over/under voltage.