Confirming Server Specifications
Optional Component Installation
Stabilize the Rack for Installation
Mounting the Server Into a 4-Post Rack
Mounting the Server Into a 2-Post Rack
Back Panel Connectors and Ports
Connect the Ethernet Network Cables
Assembling and Connecting DC Power Cords
Assemble the DC Input Power Cables
Connect the DC Input Power Cords to the Server
Powering On the Server for the First Time
Oracle ILOM System Console Overview
Connect a Terminal or Emulator to the SER MGT Port
Power On the Server for the First Time
Oracle Solaris OS Configuration Parameters
Assigning a Static IP Address to the Service Processor
Understanding System Administration Resources
Platform-Specific ILOM Features
Oracle VM Server for SPARC Overview
Reset the Server From the Oracle Solaris OS
Reset the SP to Default Values
Prepare to Use the FCode Utility
Changing Server Identification Information
Change Customer FRU Data Information
Change System Identifier Information
Restore Host Power State at Restart
Specify Host Power State at Restart
Disable or Re-Enable Power-On Delay
Specify Parallel Boot of the SP and Host
Configure Host Behavior With the Keyswitch State
Disable or Re-Enable Network Access to the SP
Display the DHCP Server IP Address
Using an In-band Connection to the SP
ILOM In-band (Sideband) Management
Configure SP In-band (Sideband) Access
Configure the Host Boot Mode of Oracle VM Server for SPARC
Change the Host Boot Mode Behavior at Reset
Manage the Host Boot Mode Script
Display Host Boot Mode Expiration Date
Override OBP Settings to Reset the Server
Configuring Server Behavior at Restart
Specify Behavior When the Host Resets
Specify Behavior When the Host Stops Running
Specify Behavior at Boot Timeout
Specify Behavior if Restart Fails
Specify Maximum Restart Attempts
Display the System Firmware Version
Display the Hypervisor Version
Power Supply, Hard Drive, and Fan Module Locations
Top Cover, Filter Tray, and DVD Tray Locations
Motherboard, DIMMs, and PCI Board Locations
Locating Components, Ports, and LEDs
Interpreting Log Files and System Messages
Verifying Oracle VTS Installation
Find the Chassis Serial Number
Component FRU Names and Service Links
Removing Power From the Server
Determine if the Hard Drive Fan Is Faulty
Servicing the Hard Drive Backplane
Determine if the Hard Drive Backplane Is Faulty
Remove the Hard Drive Backplane
Install the Hard Drive Backplane
Verify the Hard Drive Backplane
Servicing the Power Distribution Board
Determine if the Power Distribution Board Is Faulty
Remove the Power Distribution Board
Install the Power Distribution Board
Verify the Power Distribution Board
Determine if the DVD Drive Is Faulty
Determine if the LED Board Is Faulty
Determine if the Fan Board Is Faulty
Servicing the PCIe2 Mezzanine Board
Determine if the PCIe2 Mezzanine Board Is Faulty
Remove the PCIe2 Mezzanine Board
Install the PCIe2 Mezzanine Board
Verify the PCIe2 Mezzanine Board
Servicing the PCIe2 Riser Card
Locate a Faulty PCIe2 Riser Card
Remove a PCIe2 Card From the PCIe2 Mezzanine Board
Remove a PCIe2 Card From the PCIe2 Riser Card
Install a PCIe2 Card Into the PCIe2 Mezzanine Board
Install a PCIe2 Card Into the PCIe2 Riser Card
Install SAS Cable for Sun Storage 6 Gb SAS PCIe RAID HBA, Internal
Servicing the Signal Interface Board
Determine if the Signal Interface Board Is Faulty
Remove the Signal Interface Board
Install the Signal Interface Board
Verify the Signal Interface Board
Determine if the Battery Is Faulty
Determine if the ID PROM Is Faulty
Determine if the Motherboard Is Faulty
Returning the Server to Operation
Connect Power Cords to the Server
Power On the Server (Oracle ILOM)
You can access the SP on your system in multiple ways. Consider the following options and choose the access method that is best for your environment.
You can physically connect to the SP using a serial connection or a network connection. The network connection can be configured to use a static IP address or DHCP (the default). Optionally, the Netra SPARC T3-1 server can use an in-band network connection to the SP, rather than the default out-of-band network management port.
For more information on each option, see the following documentation:
To use a serial connection to the SP, see:
“Connect a Terminal or Emulator to the SER MGT Port” in the Netra SPARC T3-1Server Installation Guide
To assign a static IP address to the SP, see:
“Assign a Static IP Address to the SP” in the Netra SPARC T3-1Server Installation Guide
To use an In-band connection to the SP, see:
Oracle Integrated Lights Out Manager (ILOM) 3.0 Documentation
Broken Link (Target ID: Z40002147163)