Sun Datacenter InfiniBand Switch 36 HTML Document Collection for Firmware Version 2.0
search filter icon
search icon

Document Information

Using This Documentation

Product Notes

Related Documentation

Feedback

Support and Accessibility

Installation

Understanding the Switch

Switch Overview

Physical Specifications

Environmental Requirements

Acoustic Noise Emissions

Electrical Specifications

Network Management Connector and Pins

USB Management Connector and Pins

Data QSFP Connector and Pins

Understanding Cabling

Routing Service Cables

Understanding Data Cabling

Preparing to Install the Switch

Installation Preparation

Suggested Tools for Installation

Antistatic Precautions for Installation

Installation Responsibilities

Installation Sequence

Verify Shipping Carton Contents

Route the Data Cables

Installing the Switch

Install the Switch in the Rack

Powering On the Switch

Connecting Data cables

Verifying the InfiniBand Fabric

Administration

Troubleshooting the Switch

Switch Hardware Problems

InfiniBand Fabric Problems

Identifying LEDs

Front Status LEDs

Rear Status LEDs

Check Chassis Status LEDs

Check Network Management Port Status LEDs

Check Link Status LEDs

Check Power Supply Status LEDs

Check Fan Status LEDs

Understanding Routing Through the Switch

Switch Chip Port to QSFP Connectors and Link LED Routes

QSFP Connectors and Link LEDs to Switch Chip Port Routes

Signal Route Through the Switch

Switch GUIDs Overview

Understanding Administrative Commands

Configuration Overview

Hardware Command Overview

InfiniBand Command Overview

ILOM Command Overview

Administering the Chassis

Monitoring the Chassis

Controlling the Chassis

Administering the I4 Switch Chip

Monitoring the I4 Switch Chip

Controlling the I4 Switch Chip

Administering the Subnet Manager

Monitoring the Subnet Manager

Controlling the Subnet Manager

Administering the InfiniBand Fabric

Monitoring the InfiniBand Fabric

Controlling the InfiniBand Fabric

Configuring the Fabric Director Node List

Partitioning the InfiniBand Fabric

Remote Management

Understanding Oracle ILOM on the Switch

Oracle ILOM Overview

Supported Features

Understanding Oracle ILOM Targets

Installing the Oracle ILOM Firmware

Firmware Delivery

Acquire the Oracle ILOM Firmware Version 1.1.3

Install the Oracle ILOM Firmware Version 1.1.3

Administering Oracle ILOM (CLI)

CLI Overview

Accessing Oracle ILOM From the CLI

Switching Between the Oracle ILOM Shell and the Linux Shell

Monitoring Oracle ILOM Targets (CLI)

Controlling Oracle ILOM Targets (CLI)

Upgrading the Switch Firmware Through Oracle ILOM (CLI)

Administering Oracle ILOM (Web)

Web Interface Overview

Access Oracle ILOM From the Web Interface

Monitoring Oracle ILOM Targets (Web)

Controlling Oracle ILOM Targets (Web)

Upgrade the Switch Firmware (Web)

Using the Fabric Monitor

Access the Fabric Monitor

Fabric Monitor Features

Accessing the Rear Panel Diagram

Accessing Status Pane Information

Control Panel Function

Monitoring Parameters and Status

Administering Oracle ILOM (SNMP)

SNMP Overview

Understanding SNMP Commands

Monitoring Oracle ILOM Targets (SNMP)

Controlling Oracle ILOM Targets (SNMP)

Administering Hardware (IPMI)

ipmitool Overview

Display the Sensor States (IPMI)

Display the Sensor Information (IPMI)

Display the System Event Log (IPMI)

Display FRU ID Information (IPMI)

Display Switch Status LED States (IPMI)

Enable the Locator LED (IPMI)

Disable the Locator LED (IPMI)

Understanding Oracle ILOM Commands

cd Command

create Command

delete Command

dump Command

exit Command (ILOM)

help Command (ILOM)

load Command

reset Command

set Command

show Command

version Command (ILOM)

Service

Understanding Service Procedures

Replaceable Components

Suggested Tools for Service

Antistatic Precautions for Service

Servicing Power Supplies

Inspecting a Power Supply

Power Off a Power Supply

Remove a Power Supply

Install a Power Supply

Power On a Power Supply

Servicing Fans

Inspecting a Fan

Remove a Fan

Install a Fan

Servicing Data Cables

Inspecting the Data Cables

Remove a Data Cable

Install a Data Cable

Servicing the Battery

Remove the Switch From the Rack

Replace the Battery

Reference

Understanding Hardware Commands

Linux Shells for Hardware Commands

checkboot Command

checkpower Command

checktopomax Command

checkvoltages Command

connector Command

dcsport Command

disablecablelog Command

disablelinklog Command

disablesm Command

disableswitchport Command

enablecablelog Command

enablelinklog Command

enablesm Command

enableswitchport Command

env_test Command

exit Command (Hardware)

fdconfig Command

fwverify Command

generatetopology Command

getfanspeed Command

getmaster Command

getportstatus Command

help Command (Hardware)

listlinkup Command

matchtopology Command

setcontrolledhandover Command

setmsmlocationmonitor Command

setsmmkey Command

setsmpriority Command

setsubnetprefix Command

showfruinfo Command

showpsufru Command

showsmlog Command

showtemps Command

showtopology Command

showunhealthy Command

smconfigtest Command

smnodes Command

smpartition Command

version Command (Hardware)

Understanding InfiniBand Commands

Linux Shells for InfiniBand Commands

ibdiagnet Command

ibhosts Command

ibnetdiscover Command

ibnetstatus Command

ibnodes Command

ibportstate Command

ibroute Command

ibrouters Command

ibstat Command

ibswitches Command

ibtracert Command

perfquery Command

saquery Command

smpquery Command

Understanding SNMP MIB OIDs

OID Tables Overview

Understanding the SUN-DCS-IB-MIB MIB OIDs

Understanding the SUN-FABRIC-MIB MIB OIDs

Understanding the SUN-HW-TRAP-MIB MIB OIDs

Understanding the SUN-ILOM-CONTROL-MIB MIB OIDs

Understanding the SUN-PLATFORM-MIB MIB OIDs

Understanding the ENTITY-MIB MIB OIDs

Index

Switch Hardware Problems

This table lists situations that might occur with switch hardware and corrective steps that you can take to resolve the problem.

Situation
Corrective Steps
The Attention LED on a power supply is lit or the power supply seems dysfunctional.
  1. Check the power supply status.

    See Display Power Supply Status.

  2. Unplug the respective power cord, wait 15 minutes, then reattach the power cord.

  3. If the previous steps do not rectify the situation, replace the power supply.

    See Switch Service, servicing power supplies.

There is no network communication with the management controller.
  1. Verify that the management controller is powered without faults.

    See Check Chassis Status LEDs .

  2. Verify that there is a LinkUp condition at the network management port.

    See Check Network Management Port Status LEDs.

  3. Verfiy that the DHCP server is providing the IP address you are using to access the management controller.

    See DHCP server documentation.

  4. If you are able to access the management controller through the USB connector, restart the management controller.

    See Switch Installation, accessing the management controller and Restart the Management Controller.

  5. If you are unable to access the management controller through the USB connector, power cycle the switch.

    See Switch Service, powering off power supplies and Switch Service, powering on power supplies.

  6. If the previous steps do not rectify the situation, replace the switch.

    See Switch Service, removing the switch from the rack.

    See Switch Installation, installaing the switch into the rack.

The Attention LED on the switch chassis is lit or the management controller seems dysfunctional.
  1. If you are unable to access the management controller, power cycle the switch.

    See Switch Service, powering off the power supply and Switch Service, powering on the power supply.

  2. If you are able to access the management controller, restart the management controller.

    See Restart the Management Controller.

  3. Check overall switch health.

    See Display Switch General Health

  4. Verify that the switch is within operating temperatures and voltages.

    See Display Switch Environmental and Operational Data.

  5. If the previous steps do not rectify the situation, replace the switch.

    See Switch Service, removing the switch from the rack.

    See Switch Installation, installing the switch into the rack.

The Attention LED on a fan is lit or the fan seems dysfunctional.
  1. Check the fan speed.

    See Display Fan Status.

  2. If the previous step does not rectify the situation, replace the fan.

    See Switch Service, servicing fans.

  3. If the previous step does not rectify the situation, install the fan into another available slot.

    See Switch Service, servicing fans.

  4. If no other slots are available, replace the switch.

    See Switch Service, removing the switch from the rack.

    See Switch Installation, installing the switch into the rack.

After installation, no links are operational.
  1. Verify that there is at least one Subnet Manager active on the InfiniBand fabric.

    See Display Subnet Manager Priority, Controlled Handover State, Prefix, and Management Key.

  2. If no Subnet Manager is active, start the Subnet Manager within the switch.

    See Switch Installation, staring the Subnet Manager.

  3. If the previous steps do not rectify the situation, restart the Subnet Manager.

    See Disable the Subnet Manager and Enable the Subnet Manager.

After installation, not all links are operational.
  1. Determine which links are nonoperational.

    See Display Link Status.

  2. For links that are “Down”, disable and re-enable the respective ports.

    See Disable a Switch Chip Port and Enable a Switch Chip Port.

  3. If the previous steps do not rectify the situation, disable the respective port.

    See Disable a Switch Chip Port.

There was a power outage during a firmware update.
  1. If you are able to access the management controller, restart the management controller.

    See Restart the Management Controller.

  2. If you are unable to access the management controller, power cycle the switch.

    See Switch Service, removing the switch from the rack.

    See Switch Installation, installing the switch into the rack.

  3. Reperform the firmware upgrade.

    See Switch Remote Administration, upgrading the switch firmware.

Related Information