Go to main content

SPARC T5-1B Server Module Service Manual

Exit Print View

Updated: February 2019
 
 

Oracle ILOM Properties That Affect POST Behavior


Note - The value of keyswitch_state must be normal when individual POST parameters are changed.
Parameter
Values
Description
/HOST keyswitch_state
normal
The server can power on and run POST (based on the other parameter settings). This parameter overrides all other commands.
diag
The server runs POST based on predetermined settings.
standby
The server cannot power on.
locked
The server can power on and run POST, but no flash updates can be made.
/HOST/diag mode
none
POST does not run.
normal
POST runs according to diag level value.
/HOST/diag level
max
If diag mode=normal, runs all the minimum tests plus extensive processor and memory tests.
min
If diag mode=normal, runs minimum set of tests.
/HOST/diag trigger
none
Does not run POST on reset.
hw-change
(Default) Runs POST following a FRU replacement or an AC power cycle.
hw_change_level
  • max (default) — Runs the maximum set of tests.

  • min -- Runs the minimum set of tests.

hw_change_verbosity
  • min (default) — Displays the minimum level of output.

  • max — Displays information for each step.

  • normal — Displays a moderate amount of information, including component names and test results.

  • debug — Displays extensive debugging information.

  • none —- Disables the output.

power-on-reset
Runs POST on every power on.
power_on_level
  • max (default) — Runs the maximum set of tests.

  • min — Runs the minimum set of tests.

power_on_verbosity
  • min (default) — Displays the minimum level of output.

  • max — Displays information for each step.

  • normal —- Displays a moderate amount of information, including component names and test results.

  • debug — Displays extensive debugging information.

  • none — Disables the output.

error-reset
(Default) Runs POST if fatal errors are detected.
error_reset_level
  • max (default) — Runs the maximum set of tests.

  • min — Runs a minimum set of tests.

error_reset_verbosity
  • min (default) — Displays the minimum level of output.

  • max — Displays information for each step.

  • normal — Displays a moderate amount of information, including component names and test results.

  • debug — Displays extensive debugging information.

  • none — Disables the output.

all-resets
Runs POST after any reset.
/HOST/diag verbosity
normal
Displays all test and informational messages in POST output.
min
Displays functional tests with a banner and pinwheel in POST output.
max
Displays all test, informational, and some debugging messages in POST output.
debug
Displays extensive debugging information.
none
Does not display POST output.

This flowchart illustrates the same set of Oracle ILOM set command variables.

image:Flow chart showing the Oracle ILOM properties used to manage POST operations

Related Information