Go to main content

SPARC T5-1B Server Module Service Manual

Exit Print View

Updated: February 2019
 
 

Check for Faults

The fmadm faulty command displays the list of faults detected by PSH. You can run this command from either the Oracle Solaris OS or through the Oracle ILOM fault management shell.

The example used in this procedure checks for faults through Oracle ILOM.

If you are accessing the server module from the CMM, prepend each target path with /Servers/Blades/Blade_n, where n is the slot in which the server module is installed. For example, start /SP/faultmgmt/shell should be entered as start /Servers/Blades/Blade_n/SP/faultmgmt/shell.

  1. Access Oracle ILOM or log into the Oracle Solaris OS.

    See Log Into Oracle ILOM (Service).

  2. (Oracle ILOM) Start the Oracle ILOM fault management shell.

    Skip this step if you are checking for faults through the Oracle Solaris OS.

    -> start /SP/faultmgmt/shell
    Are you sure you want to start /SP/faultmgmt/shell
    (y/n)? y
     
    faultmgmtsp>
    
  3. Check for PSH-diagnosed faults.

    This example shows how to check for faults through the Oracle ILOM fault management shell.

    faultmgmtsp> fmadm faulty
    ------------------- ------------------------------------ -------------- --------
    Time                UUID                                 msgid          Severity
    ------------------- ------------------------------------ -------------- --------
    2013-01-08/12:13:42 59b2d926-4896-e979-e85c-cfedb5daedf5 SPSUN4V-8000-F2 Major
     
    Problem Status    : solved
    Diag Engine       : fdd 1.0
    System
     
    System Component
       Manufacturer   : Oracle Corporation
       Name           : SPARC T5-1B
       Part_Number    : 7023631-04
       Serial_Number  : 465769T+1219EK001X
     
    ----------------------------------------
    Suspect 1 of 1
       Fault class  : fault.memory.dimm-ue
       Certainty    : 100%
       Affects      : /SYS/MB/CM0/CMP/BOB6/CH1/D0
       Status       : faulted but still in service
     
       FRU
          Status            : faulty
          Location          : /SYS/MB/CM0/CMP/BOB6/CH1/D0
          Manufacturer      : Samsung
          Name              : 8192MB DDR3 SDRAM DIMM
          Part_Number       : 07042208,M393B1K70DH0-YK0
          Revision          : 02
          Serial_Number     : 00CE0212133341DB80
          Chassis
     
    Description : Description associated with fault.memory.dimm-ue
     
    Response    : Response associated with fault.memory.dimm-ue
     
    Impact      : Impact associated with fault.memory.dimm-ue
     
    Action      : Use 'fmadm faulty' to provide a more detailed view of this
                  event. Action associated with fault.memory.dimm-ue Please
                  refer to the associated reference document at
                  http://support.oracle.com/msg/SPSUN4V-8000-F2 for the latest
                  service procedures and policies regarding this diagnosis.
    

    In this example, a fault is displayed, indicating these details:

    • Date and time of the fault (2013-01-08/12:13:42).
    • UUID (59b2d926-4896-e979-e85c-cfedb5daedf5), which is unique for every fault. This is sometimes identified as an Event ID.
    • Message identifier (SPSUN4V-8000-F2), which can be used to obtain additional fault information.
    • Faulted component, including these details:
      • Component name (/SYS/MB/CM0/CMP/BOB6/CH1/D0)

      • Part number (07042208,M393B1K70DH0-YK0)

      • Serial number (00CE0212133341DB80)

  4. Use the message ID to obtain more information about this type of fault:
    1. Obtain the message ID from console output.
    2. Log into My Oracle Support at: https://support.oracle.com
    3. Search on the message ID.
  5. Follow the suggested actions to repair the fault.
  6. If necessary, clear the fault manually.

    See Clear a Fault.

Related Information