The fmadm faulty command displays the list of faults detected by PSH. You can run this command from either the Oracle Solaris OS or through the Oracle ILOM fault management shell.
The example used in this procedure checks for faults through Oracle ILOM.
If you are accessing the server module from the CMM, prepend each target path with /Servers/Blades/Blade_n, where n is the slot in which the server module is installed. For example, start /SP/faultmgmt/shell should be entered as start /Servers/Blades/Blade_n/SP/faultmgmt/shell.
Skip this step if you are checking for faults through the Oracle Solaris OS.
-> start /SP/faultmgmt/shell Are you sure you want to start /SP/faultmgmt/shell (y/n)? y faultmgmtsp>
This example shows how to check for faults through the Oracle ILOM fault management shell.
faultmgmtsp> fmadm faulty
------------------- ------------------------------------ -------------- --------
Time UUID msgid Severity
------------------- ------------------------------------ -------------- --------
2013-01-08/12:13:42 59b2d926-4896-e979-e85c-cfedb5daedf5 SPSUN4V-8000-F2 Major
Problem Status : solved
Diag Engine : fdd 1.0
System
System Component
Manufacturer : Oracle Corporation
Name : SPARC T5-1B
Part_Number : 7023631-04
Serial_Number : 465769T+1219EK001X
----------------------------------------
Suspect 1 of 1
Fault class : fault.memory.dimm-ue
Certainty : 100%
Affects : /SYS/MB/CM0/CMP/BOB6/CH1/D0
Status : faulted but still in service
FRU
Status : faulty
Location : /SYS/MB/CM0/CMP/BOB6/CH1/D0
Manufacturer : Samsung
Name : 8192MB DDR3 SDRAM DIMM
Part_Number : 07042208,M393B1K70DH0-YK0
Revision : 02
Serial_Number : 00CE0212133341DB80
Chassis
Description : Description associated with fault.memory.dimm-ue
Response : Response associated with fault.memory.dimm-ue
Impact : Impact associated with fault.memory.dimm-ue
Action : Use 'fmadm faulty' to provide a more detailed view of this
event. Action associated with fault.memory.dimm-ue Please
refer to the associated reference document at
http://support.oracle.com/msg/SPSUN4V-8000-F2 for the latest
service procedures and policies regarding this diagnosis.
In this example, a fault is displayed, indicating these details:
Component name (/SYS/MB/CM0/CMP/BOB6/CH1/D0)
Part number (07042208,M393B1K70DH0-YK0)
Serial number (00CE0212133341DB80)
See Clear a Fault.