Install the Power, FIM, Disk Backplane Data, and DVD Cables


Caution  -  The Power, front indicator module, disk backplane data, and DVD cables should be installed only by authorized Oracle Services personnel.


  1. Install the DVD cable.
    1. Connect the DVD cable to the rear of the DVD drive and the DVD power connector to the disk backplane.
    2. Connect connect the DVD cable to the motherboard [7].

      For reference, use the illustration provided in Removing the Power, FIM, Disk Backplane Data, and DVD Cables.

    3. If you removed a PCIe card from PCIe slot 2, install the PCIe riser and card into PCIe slot 2.

      See Install a PCIe Riser Into PCIe Slot 1 or 2

  2. Install the FIM cable.
    1. To install the FIM cable into the motherboard, open both side latches and plug the FIM connector into motherboard connector [6].

      The motherboard connector side latches will close, locking the FIM cable connector in place.

    2. Connect the FIM cable to the FIM [5].
    3. Install the FIM into the server.

      See Install the Front Indicator Module

  3. Install the Auxiliary power and signal cable.
    1. To install the auxiliary power and signal cable into the disk backplane, ensure that the latches on the disk backplane connector are in the open position and plug the cable connector into the disk backplane connector [4].

      The disk backplane connector side latches will close, locking the auxiliary power and signal cable connector in place.

    2. To install the auxiliary power and signal cable into the motherboard, ensure that the latches on the motherboard connector are in the open position and plug the cable connector into the motherboard connector [3].

      The motherboard connector side latches will close, locking the auxiliary power and signal cable connector in place.

  4. Install the disk backplane power cable.
    1. To connect the disk backplane power cable to the disk backplane, plug the cable connector into the disk backplane connector. [2].
    2. To connect the disk backplane power cable to the motherboard, plug the cable connector into the motherboard connector. [1].
  5. Install all of the server fan modules.

    See Install a Fan Module.

  6. Return the server to operation.
    1. Install the server top cover.

      See Install the Server Top Cover.

    2. Close the server fan door.
    3. Return the server to the normal rack position.

      See Return the Server to the Normal Rack Position.

    4. Power on the server.

      See Power On the Server.

      Verify that the Power/OK status indicator is steady on.