Oracle® Server X6-2 Service Manual

Exit Print View

Updated: January 2021
 
 

Remove the Front Indicator Module


Caution  -  The front indicator module should be removed only by authorized Oracle Services personnel.


  1. Prepare the server for service.
    1. Power off the server and disconnect the power cords from the power supplies.

      See Powering Down the Server.

    2. Extend the server to the maintenance position.

      See Extend the Server to the Maintenance Position.

    3. Attach an antistatic wrist strap to your wrist, and then to a metal area on the chassis.

      See Take Antistatic Measures.

  2. To remove the top cover from the storage drive cage, do the following [1]:
    1. Remove the six Phillips screws from the top of the storage drive cage.

      There are three Phillips screws on each side of the storage drive cage.

    2. Open the server fan door.

      See Open the Server Fan Door.

    3. Slide the storage drive cage cover forward (toward the front of the server) and lift it up.
      image:Figure showing how to remove the front indicator module                                         (FIM) from the server.
  3. Loosen the screw that secures the front indicator module (FIM) assembly to the server chassis [2].
  4. Carefully slide the FIM assembly toward the rear of the server enough to lift it over the Phillips screw and out of the server [2].
  5. Disconnect the FIM cable from the FIM assembly and set the assembly aside [3].
  6. Continue to Install the Front Indicator Module .