Go to main content

Oracle® Server X6-2 Service Manual

Exit Print View

Updated: January 2021
 
 

Install the Internal HBA SAS Cable Assembly


Caution

Caution  -  The internal HBA SAS cable assembly should be installed only by an Oracle qualified service technician.


  1. Carefully guide SAS cables and the super capacitor cable along the side of the chassis.
  2. Connect the super capacitor cable to the super capacitor [3].

    For reference, use the illustration provided in Remove the Internal HBA SAS Cable Assembly.

  3. Connect the SAS cables the super capacitor cable to the internal HBA card [2].
  4. Install the SAS cables into the disk backplane [1].
  5. Install the PCIe riser with the internal HBA card into PCIe slot 3.

    See Install the PCIe Riser Into PCIe Slots 3 and 4.

  6. Install all of the server fan modules.

    See Install a Fan Module.

  7. Return the server to operation.
    1. Install the server top cover.

      See Install the Server Top Cover.

    2. Close the server fan door.
    3. Return the server to the normal rack position.

      See Return the Server to the Normal Rack Position.

    4. Reconnect the data cables to the server and reconnect the power cords to the server power supplies.

      See Reconnect Data Cables and Power Cords.

    5. Power on the server.

      See Power On the Server.

      Verify that the Power/OK status indicator is steady on.

Related Information