Oracle® Server X6-2 Service Manual

Exit Print View

Updated: January 2021
 
 

Remove and Install Filler Panels

  • See the procedures in the following table to remove and install filler panels for storage drives and PCIe cards.
    Filler Panel Type
    Removal Procedure
    Installation Procedure
    Storage Drive
    1. Locate the storage drive filler panel to be removed from the server.

    2. To unlatch the storage drive filler panel, pull the release lever, and then tilt the lever out into a fully opened position.

    3. To remove the filler panel from the slot, hold the opened release lever, and gently slide the filler panel toward you.

    1. Locate the vacant storage drive module slot in the server, and then ensure that the release lever on the filler panel is fully opened.

    2. Slide the filler panel into the vacant slot by pressing the middle of the filler panel faceplate with your thumb or finger.

    3. The release lever will close as it makes contact with the chassis. Do not slide the filler panel in all the way. Leave the filler panel out approximately 0.25 to 0.50 inch (6 to 12 mm) from the opening.

    4. Using your thumb or finger, press on the middle of the filler panel faceplate until the release lever engages with the chassis.

    5. Close the release lever until it clicks into place and is flush with the front of the server

    PCI Slot
    1. Remove the server top cover.

    2. To remove the PCIe slot filler panel, rotate the PCIe locking mechanism, and then lift and remove the PCIe slot filler panel from the location into which you intend to install the PCIe card. Note: In single-processor systems, PCIe slot 1 is nonfunctional; therefore, there is no need to remove the filler panel for slot 1

    1. Remove the server top cover.

    2. To install the PCIe slot filler panel, press the PCIe filler panel into the vacant PCIe slot, and then rotate the PCIe locking mechanism to secure the PCIe slot filler panel. Note: In single-processor systems, PCIe slot 1 is nonfunctional; therefore, the server ships with this filler panel installed.