Go to main content

Oracle® Server X6-2 Service Manual

Exit Print View

Updated: January 2021
 
 

System Board Components

The following table lists the system board components.

Component Name (Oracle ILOM CLI Targets)
IPMI Type
Description
Values (if applicable)
/SYS/MB
FRU
General host system board FRU
/SYS/MB/CPLD
FRU
Mainboard CPLD/FPGA firmware version
/SYS/MB/NET[0-3]
FRU
Host Ethernet FRU
/SYS/MB/RISER[1-3]/PRSNT
Discrete sensor
PCIe riser inserted into PCIe slot
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/MB/RISER1/PCIE1/PRSNT
Discrete sensor
Option card inserted into PCIe riser 1
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/MB/RISER2/PCIE2/PRSNT
Discrete sensor
Option card inserted into PCIe riser 2
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/MB/RISER3/PCIE3/PRSNT
Discrete sensor
Option card inserted into slot 3 of PCIe riser 3
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/MB/RISER3/PCIE4/PRSNT
Discrete sensor
Internal HBA card inserted into slot 4 of PCIe riser 3
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/MB/RISER1/PCIE1/PCIESW
FRU
Optional Oracle PCIe NVMe switch card, dedicated slot
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/MB/RISER1/PCIE1/PCIESW/PRSNT
FRU
Optional Oracle PCIe NVMe switch card inserted into slot 1 of PCIe riser 1, dedicated slot
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/MB/T_OUT_SLOT[1-3]
Threshold sensor
Cooling zone chassis exhaust temperature, located behind the specified PCIe slots.
  • Slot 1 – PCIe slot 1

  • Slot 2 – PCIe slot 2

  • Slot 3 – PCIe slot 3

Degrees Celsius
/SYS/MB/T_IN_SLOT[1-3]
Threshold sensor
Cooling zone chassis inlet temperature, located in front of the specified PCIe slots.
  • Slot 1 – PCIe slot 1

  • Slot 2 – PCIe slot 2

  • Slot 3 – PCIe slot 3

Degrees Celsius
/SYS/MB/T_CORE_NET01
Threshold sensor
Gigabit Ethernet controller die temperature
CPU 0, NET 0+1 Degrees Celsius
/SYS/MB/T_CORE_NET23
Threshold sensor
Gigabit Ethernet controller die temperature
CPU 1, NET 2+3 Degrees Celsius
/SYS/MB/T_IN_SLOT[1-3]
Threshold sensor
PCIE slot input temperature
Degrees Celsius
/SYS/MB/T_OUT_SLOT[1-3]
Threshold sensor
PCIE slot output temperature
Degrees Celsius
/SYS/MB/T_IN_PS
Threshold sensor
Power supply unit (PSU) inlet temperature, located directly in front of the PSU 0 air inlet.
Degrees Celsius
/SYS/SP
FRU
Service processor FRU
/SYS/SP/OK
Indicator
SP OK LED
Color: Green
Location: Front panel
On: SP is operating.
Off: SP requires service.
/SYS/SP/NET[0-1]
FRU
SP Ethernet FRU

Related Information